![Belden Hirschmann MIPP Description And Assembly Instructions Download Page 20](http://html1.mh-extra.com/html/belden/hirschmann-mipp/hirschmann-mipp_description-and-assembly-instructions_2725485020.webp)
20
MIPP
Release 01 01/12
3
Expanding the device
You have the following options to expand the device according to your needs:
Add module to device
Add RJ45 Keystone jacks to CU modules
3.1
Assembly of LC, SC and CU modules
The device can be expanded until the total of 6 single modules. 1 double
module can be used instead of 2 single modules.
The following sequence has proven itself in practice during installation:
Remove device
Expand housing for additional modules
Install the installation cable on the modules
Mount modules in the housing
Mount device on the DIN rail or wall mounting plate
Connect device
You will require the following tools (not included in the delivery):
Hexagon socket wrench
Screw driver
Prepare the following device components:
2 housing bolts with the respective length (a total of 30 mm per single
module, 60 mm per double module; see
page 22 “General technical data”
and
page 23 “Accessories and order numbers”
1 slider with the respective length (a total of 30 mm per single module,
60 mm per double module; see
page 22 “General technical data”
page 23 “Accessories and order numbers”
)
Spacer with divider
3.1.1
Disassembling the device
Proceed as follows:
Remove the patch cable from the device.
Remove the modules.
Press the device down and push forward away from the rail.
Summary of Contents for Hirschmann MIPP
Page 26: ......