![Belden Hirschmann MIPP Description And Assembly Instructions Download Page 16](http://html1.mh-extra.com/html/belden/hirschmann-mipp/hirschmann-mipp_description-and-assembly-instructions_2725485016.webp)
16
MIPP
Release 01 01/12
2.2.2
Installation of installation cables on LC and SC
modules
Proceed as follows:
Loosen the cable gland.
Guide the installation cable through the cable gland in the module.
Remove the jacket from the installation cable to a sufficient length for
termination.
When using a double module: Install 12 fibers on both sides.
Tighten the cable gland.
Fix the strain relief.
Note:
Follow the safety instruction from the splicer manufacturer.
Note:
When performing fusion splicing, we recommend you to use heat
shrink protectors with a diameter of 1.3 mm after shrinkage and a length of
25 to 35 mm.
Note:
When performing mechanical splicing, we recommend you to use
crimp splice protectors with a width of 1.3 mm and a length of 25 to 35 mm.
A) Splice the pigtails to the fibers of the installation cable and fix the splice
position in the splice holder.
Or:
B) Terminate the fibers with the Brilliance connectors.
Place the fiber into the fiber bracket.
Note:
The module has space for a maximum of 15 m of fiber supply.
Insert the connectors into the adapters until it locks into place.
2.2.3
Installation of installation cables on CU modules
Proceed as follows:
Install the installation cables into the RJ45 Keystone jacks (see product
documentation from the Keystone jacks manufacturer).
Press the Keystone jacks into the cutout in the module until it locks into
place, beginning with cable 3, and continuing with cable 4, then cable 2
and finally cable 1
(see fig. 17 “Cables arrangement – Top view”)
.