Safety instructions
Certified usage
Only use the device for application cases that are described in the
Hirschmann product information, including this manual. Only operate the
device according to the technical specifications.
Supply voltage
The supply voltage is electrically isolated from the housing.
Solely connect a supply voltage that corresponds to the type plate of
your device.
This applies to the following device variants only:
MACH104-16TX-PoEP-E...
MACH104-16TX-PoEP+2X-E...
Install an input fuse with a maximum rating of 10 A, characteristic B,
into the supply line to the voltage input.
Use conductors with a minimum cross-section of 1 mm
2
for the supply
line to the voltage input.
Exclusively connect SELV circuits with the voltage restrictions in
accordance with IEC/EN 60950-1 to the supply voltage connections.
Ensure that the connected supply voltage complies with the
requirements according to IEEE 802.3af or IEEE 802.3at.
Use undamaged parts.
The device does not contain any service components. Internal fuses
are only triggered if there is a fault in the device. If the device is not
functioning correctly, or if it is damaged, switch off the voltage supply
and return the device to the plant for inspection.
Only switch on the device when the housing is closed.
Only use connection cables that are permitted for the specified
temperature range.
Relevant for North America:
Only use copper wire/conductors of class 1, 60/75°C or 75°C.
Make sure that the disconnecting device is easily accessible so that
the MACH104-PoEP device can be disconnected from the mains
voltage.
If you disconnect the device from the mains voltage using
- the plug in the socket
- an on/off switch
it must be easily accessible.
This applies to the following device variants only:
MACH104-16TX-PoEP-R...
MACH104-16TX-PoEP+2X-R...
Pull
both
non-heating plugs to disconnect the device from mains
voltage.