44
Installation BAT867-R
Release 10 09/2021
10 Technical data
10.1
General technical data
Dimensions
W × H × D
BAT867-R
See “Dimension drawings” on page 45.
Weight
520 g (18.3 oz)
Supply voltage
Rated voltage
24 V DC
Voltage range incl. maximum
tolerances
18 V DC ... 32 V DC
Connection type
2-pin terminal block
Power loss buffer
10 ms at 24 V DC
Overload current protection on
the device
Non-replaceable fuse
Back-up fuse
Nominal rating: 3.5 A
Characteristic:
slow blow
Peak inrush current (slow
voltage increase)
850 mA
Current integral I²t
0.373 A
2
s
Climatic
conditions during
operation
Minimum clearance around the
device
Top and bottom sides of device: 5 cm (2 in)
Left and right device side: 2 cm (0.79 in)
Ambient air temperature
a
a. Temperature of the ambient air at a distance of 5 cm (2 in) from the device
-10 °C ... +60 °C (+14 °F ... +140 °F)
Maximum inner temperature of
device (guideline)
+90 °C (+194 °F)
Humidity
10 % ... 95 % (non-condensing)
Air pressure
min. 700 hPa (+3000 m ASL; +9842 ft ASL)
max. 1060 hPa (-400 m ASL; -1312 ft ASL)
Climatic
conditions during
storage
Ambient air temperature
a
-40 °C ... +70 °C (-40 °F ... +158 °F)
Humidity
10 % ... 95 % (non-condensing)
Air pressure
min. 700 hPa (+3000 m ASL; +9842 ft ASL)
max. 1060 hPa (-400 m ASL; -1312 ft ASL)
Pollution degree
2
Protection classes Degree of protection
IP40
b
b. for DIN rail mounting
Summary of Contents for Hirschmann BAT867-R