
42
Installation BAT450-F
Release 12 07/2020
2.4.1
Supply voltage with the characteristic value W
(24 V DC)
For
every
supply voltage to be connected, perform the following steps:
Connect the wires for the supply voltage according to the pin assignment
with a suitable socket.
2.4.2
Supply voltage with the characteristic value N
(110 V DC)
For
every
supply voltage to be connected, perform the following steps:
Connect the wires for the supply voltage according to the pin assignment
with a suitable socket.
Type and specification of the supply
voltage
Pin assignment on the device
Rated voltage DC:
24 V DC
1 +24 V DC
Voltage range DC incl. maximum
tolerances:
16.8 V DC ... 32 V DC
2 0 V DC
3 0 V DC
4 N.C.
5 N.C.
Table 6:
Type and specification of the supply voltage
WARNING
ELECTRIC SHOCK
Exclusively install this device in a restricted access location, to which
maintenance staff have exclusive access. Install the device in such a way
that it is protected against mechanical forces in the area of the power
supply.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
Type and specification of the supply
voltage
Pin assignment on the device
Rated voltage DC:
110 V DC
1 N.C.
Voltage range DC incl. maximum
tolerances:
77 V DC ... 138 V DC
2 +110 V DC
3 0 V DC
4 N.C.
Table 7:
Type and specification of the supply voltage
4
3
2
1
5
1
2
3
4