58
Installation
MTS8003/8006/8010
Release 01 12/2021
2.5
Operating the device
Perform the following work steps:
Connect the power supply cable.
Enable the power supply.
2.6
Connecting the data cables
Note the following general recommendations for data cable connections in
an environments with high electrical interference levels:
Keep the length of the data cables as short as possible.
Use optical fiber data cable for data transmission between the buildings.
When using copper cables, provide a sufficient separation between the
power supply cables and the data cables. Ideally, install the cables in
separate cable channels.
Verify that power supply cables and data cables do not run parallel over
longer distances. To reduce inductive coupling, verify that the power
supply cables and data cables cross at a 90° angle.
Use SF/UTP cables
according to ISO/IEC 11801:2002.
Connect the data cable according to your need.
Connect the data cable according to your requirements.
See “Device name and product code” on the page 26.
2.7
Filling out the inscription label
The information field for the MAC address helps you identify your device.
Summary of Contents for HIRESCHMANN IT MAMMUTHUS MTM8003-FAN
Page 68: ...Installation MTS8003 8006 8010 Release 01 12 2021 68 MTS8006 Chassis ...
Page 69: ...Installation MTS8003 8006 8010 Release 01 12 2021 69 MTS8010 Chassis ...
Page 70: ...Installation MTS8003 8006 8010 Release 01 12 2021 70 Power module ...
Page 71: ...Installation MTS8003 8006 8010 Release 01 12 2021 71 Engine module ...
Page 72: ...Installation MTS8003 8006 8010 Release 01 12 2021 72 Fan module MTS8003 FAN ...
Page 73: ...Installation MTS8003 8006 8010 Release 01 12 2021 73 MTS8006 FAN ...
Page 74: ...Installation MTS8003 8006 8010 Release 01 12 2021 74 MTS8010 FAN ...
Page 84: ...Installation MTS8003 8006 8010 Release 01 10 2021 84 ...