GUIDE TO INSTALLATION AND OPERATION
4
| XVP-3901-DPI
2 Installation
2.1 Installation of Rear Connector Panels
The XVP-3901-DPI card is designed to fit into Grass Valley’s Densité-3 frame.
Grass Valley Densité-series cards are each associated with a rear connector panel, which must be installed in the
Densité frame before the card can be inserted. Two rear panels are available for the XVP-3901-DPI:
•
XVP-3901-75-3DRP-R
Double-slot-width panel with 75
Ω
audio and bypass relay.
•
XVP-3901-110-3DRP-R-F Double-slot-width panel with 110
Ω
audio, bypass relay and fiber I/O.
See section 2.5 for details of the signal connections available on each of these panel types.
All cards and rear panels can be installed with the frame power on. The card has connectors which plug into a mid-
frame mother board for distribution of power and for connection to the controller card, and a second connector which
plugs directly into the rear connector panel for input and output.
The rear connector panel must be installed with the card out of the frame.
•
To remove an existing card from the slot, tilt up the swivel handle on the front of the card to lever the connectors
apart, then use the handle to pull the card straight out of the slot.
Figure 2.1 Densité-3 frame – rear panel installation
To install the connector panel:
1. If a card is installed in the slot whose rear panel is being changed, remove it as described above.
2. Remove the existing panel (either blank or belonging to an existing card that is being changed) by releasing the
captive screw(s) at the bottom.
Summary of Contents for Grass Valley XVP-3901-DPI
Page 4: ...GUIDE TO INSTALLATION AND OPERATION XVP 3901 DPI ...
Page 78: ...GUIDE TO INSTALLATION AND OPERATION 72 XVP 3901 DPI ANNEX 1 XVP 3901 Local User Interface ...
Page 79: ...GUIDE TO INSTALLATION AND OPERATION XVP 3901 DPI 73 ...
Page 80: ...GUIDE TO INSTALLATION AND OPERATION 74 XVP 3901 DPI ...
Page 81: ...GUIDE TO INSTALLATION AND OPERATION XVP 3901 DPI 75 ...