XCU Universe XF XF Transmission Base Station User’s Guide (v1.4)
57
Chapter 6 - Connectors and signals
Area 2: Reference connectors
*) This output signal is always looped-through even when the XCU is not mounted in its cradle.
☞
Note
☞
Note
The last loop-through output in a chain must be terminated with a 75
resistor. The maximum
number of XCUs that can be looped through is 6.
6.1.9 Signalling connector
Connector
Signal
Ref in
Reference input signal (HD Tri-Level sync or SD Black Burst are accepted)
Ref out
Reference loop-through output signal *)
Pin Description
1
Preview output ext. (relay
contact < 10
)
2
Call output ext. (relay contact
< 10
)
3
ISO input ext. (dry contact)
4
On Air input ext. (dry contact)
5
Call input ext. (dry contact)
6
Audio 1 level (analog input
voltage from 0 to 5 V)
7
5 V (Operating Control Panel)
1
15
Microphone impedance >200
sensitivity range: -70 to -28 dBm
Signal at pin 2 of audio input is in phase with signal at pin 2 of the audio output.
Shield of cable to the pin marked housing.
SubD 15-pin male
connector
Pin Description
8
Housing
9
Preview output ext. return
10
Call output ext. return
11
ISO input ext. return
12
On Air input ext. return
13
Call input ext. return
14
Audio 2 level (analog input
voltage from 0 to 5 V)
15
GND
Summary of Contents for Grass Valley XCU Universe XF
Page 32: ...32 XCU Universe XF XF Transmission Base Station User s Guide v1 4 Chapter 3 Configuration...
Page 50: ...50 XCU Universe XF XF Transmission Base Station User s Guide v1 4 Chapter 5 XCU menu reference...
Page 64: ...64 XCU Universe XF XF Transmission Base Station User s Guide v1 4 Chapter 7 Specifications...
Page 65: ...XCU Universe XF XF Transmission Base Station User s Guide v1 4 65...