The select button allows you to access and set basic configuration parameters. The use of
the select button is described in
Changing the Mosaic Output Resolution
For more information about the USB port, see
Troubleshooting with the card's front edge
Using the Frame Control Panel
All of the cards installed in a Densité 3+ FR1 or Densité 3+ FR4 frame are connected to the
frame’s controller card, which handles all interaction between the cards and the outside
world. There are no operating controls located on the cards themselves. The controller
supports remote operation via its Ethernet ports, and local operation using its integrated
control panel.
CPU-ETH2 Local Control Panel
In the case of a Densité 3+ FR1 frame, the local control panel is fastened to the CPU-ETH2
controller card, and consists of a display unit capable of displaying two lines of text, each
16 characters in length, and five buttons.
CPU-ETH2 local control panel
The panel is assigned to operate any card in the frame by pressing the Select button
on the
front edge of that card.
The Status LED on the selected card will then be flashing orange.
Press the CONTROLLER button on the control panel to select the controller card itself.
CPU-ETH3 Local Control Panel
The CPU-ETH3 local control panel is located in the top right side of the Densité 3+ FR4
frame. The control interface is a touch screen that allows you to view the status of
Densité 3+ FR4 frame components including that of each card currently installed in the 24
slots. A number of buttons (PS1, PS2, FANs, CTRL, and REF) allow you to access the menus
for the Densité 3+ FR4 frame components including its reference module. The outline color
of the buttons behave like status indicators. For example, in the image below, the card in
slot 13 is in alarm.