23
Technical Specifications
Inputs, Outputs and Controls
Inputs/Outputs
RollCall Remote Control
BNC connector
RS-422/485/232 Remote Control
9-pin, D-type connector
RollCall/SNMP over TCP/IP
10/100 baseT Ethernet
Video Reference
BNC connector x 2
PSU Status
Molex connector x2 (Molex Header part number: 22-27-2031)
Preset Controls
Unit address code set switches
2 Hex switches 0 to F
Communications mode switch
Select RS-232, RS-485 or RS-422 interface
Additional Controls via RollCall Remote Control System
Full Control via web browser based Java RollCall control panel (available from chassis), any hardware RollCall control
surface or standard RollCall Control Panel PC Application.
Specifications
Modules
Module Complement
8 double width or 16 single width (or combinations of both) fitted
vertically
Module Card Dimensions
100 mm wide, 340 mm long
Module Rear Panel Dimensions
129 mm high (-A versions and -B versions), 40.4 mm (double width), 20 mm
(single width) wide
Power
Input Voltage Range
100-240 V 50/60 Hz
Input Connector
IEC320 Fused 4 A(T)
Standby Switch
Behind drop-down front panel
Power Consumption
300 VA maximum
Modules Power Dissipation
IQH3B - 165 LU maximum
IQH3BQ - 100 LU maximum
Power is quoted in Load Units (LU) and is taken from the positive rail only.
Output
+7.5 V and -7.5 V ± 5%
Note that all modules have built-in power supply fuses
CE Performance Information
Environment
Commercial and light industrial E2 immunity, controlled EMC E4 emissions
Peak Mains Inrush Current following a
5 second mains interruption
10 A