Belden grass valley GV K-FRAME X Installation Planning Manual Download Page 1

Installation Planning Guide

13-00010-000AA

2/22/18 

GV K-FRAME X 

VIDEO PRODUCTION FRAMES

Summary of Contents for grass valley GV K-FRAME X

Page 1: ...Installation Planning Guide 13 00010 000AA 2 22 18 GV K FRAME X VIDEO PRODUCTION FRAMES...

Page 2: ...ame Video Production Switchers to use their product manuals for their own internal business use Manuals for Grass Valley products may not be reproduced or transmitted in any form or by any means elect...

Page 3: ...the text must be replaced with one having the ratings indicated Identifies a protective grounding terminal which must be connected to earth ground prior to making any other equipment connections Iden...

Page 4: ...cleaning the equipment Do not use liquid or aerosol cleaners use only a damp cloth Dangerous voltages may exist at several points in this equipment To avoid injury do not touch exposed connections and...

Page 5: ...fied to do so Refer all servicing to qualified service personnel Servicing should be done in a static free environment This unit may have more than one power supply cord Disconnect all power supply co...

Page 6: ...ution should be exercised at all times Mesures de s curit et avis importants Signification des symboles utilis s vi Avertissements vii Mises en garde viii La pr sente section fournit des consignes de...

Page 7: ...d un cordon d alimentation et qu il faut d brancher tous les cordons d alimentation avant toute op ration d entretien afin de pr venir les chocs lectriques La marque C CSA US certifie que l appareil v...

Page 8: ...ue l appareil est sous tension Avant de proc der toute op ration d entretien ou de d pannage enlevez tous vos bijoux notamment vos bagues votre montre et autres objets m talliques Pour viter tout risq...

Page 9: ...qui peut entra ner des d faillances intermittentes ou endommager irr m diablement un circuit lectrique Au moment de remplacer une carte dans un ch ssis prenez toujours les mesures de protection antist...

Page 10: ...laver imm diatement l eau savonneuse Ne jamais ing rer le liquide La toxicit est extr mement faible mais la prudence demeure de mise en tout temps Recycling Visit www grassvalley com for recycling in...

Page 11: ...O O O O O Fan Assemblies X O O O O O Metal Parts X O O O O O Plastic and Polymeric Parts X O O O O O KOR PNL 100 15 KOR PNL 200 20KRR ELITE 25 PS and KRR ELITE 35 PS Part name Toxic or hazardous Subs...

Page 12: ...l explanations This statement is based on the information provided by our suppliers of components and collected through our Grass Valley s environmental management system Grass Valley believes this en...

Page 13: ...f necessary 4 Dispose of the battery and equipment according to your local environmental laws and guidelines WARNING Be careful not to short circuit the batteries by adhering to the appropriate safe h...

Page 14: ...ity EN 61000 4 6 Conducted disturbances immunity EN 61000 4 8 Power frequency magnetic field immunity EN 61000 4 11 Voltage dips short interruptions and voltage variations immunity Note This equipment...

Page 15: ...a Control Surface 9 Multiple Suites and Control Surfaces Example 10 Soft Panel KSP Option 12 Menu Application 12 Supported Control Protocols 13 2 Frame Installation 15 15 RU Video Processor Dimensions...

Page 16: ...Cabling 37 IP I O Fiber Optic Cabling 37 SDI Inputs and Outputs 37 IP I O 38 Reference Input 38 Supported Media Port Line and Frame Rates 38 System Video Timing and Delay 38 Timing Analyzer 40 Time Zo...

Page 17: ...xternal devices DDRs Servers and bi directional control to and from routing and automation systems Features General Fully digital 10 bit 4 2 2 video switcher including 4K HDR HLG and PQ and1080p suppo...

Page 18: ...ources Settings for On Off As Is on every M E Full look ahead preview of rules Hot swappable front rear removable modules and power supplies Optional multiple Multiviewer capability with 5 pre configu...

Page 19: ...UTION Do not connect or disconnect the PCU to Control Panel cables while the system is powered on 4 ME 35 Control Panel Menu Panel Menu Panel Articulated Arm 8623266_01 Panel Control Unit PCU Optional...

Page 20: ...reen display An articulated arm is also included offering a wide variety of installation options The Menu Panel has a standard VESA 75 hole pattern and M4 threads compatible with this and many other m...

Page 21: ...keyboard control from a laptop or remote control from any location on the network Basic Single Suite Kayenne Panel System A basic K Frame system consists of a Control Panel a Menu application running...

Page 22: ...ideo Processor Frame can be assigned to an individual suite during configuration essentially creating two separate switchers sharing one frame Kayenne Control Panel Multi Suite Standard Frame Example...

Page 23: ...nu Panel has a standard VESA 75 hole pattern and M4 threads compatible with this and many other mounting devices The Menu Panel also has four USB ports two on the right side edge of the panel and two...

Page 24: ...surface associated with that frame Karrera Single Suite Compact Frame Example Multiple Suites and Control Surfaces A K Frame system can be subdivided into two suites if desired each of which can have...

Page 25: ...ols Controls for background and keyer source selection Multi Function and E MEM area Horizontal keyer cut mix Multi function keypad and display and Includes a built in multi touch display and menu sys...

Page 26: ...igured with any GV K Frame X Video Processor The system can be subdivided into two suites and each suite can have up to two control surfaces Hardware resources in the Video Processor Frame can be assi...

Page 27: ...Example 6600_40 Suite 1 2 M E 25 Karrera Control Panel Karrera Menu on PC Customer Supplied PC Suite 2 Standard 15 RU GV K Frame X 2 M E 20 GV Korona Control Panel Menu Panel Menu Panel Articulated Ar...

Page 28: ...080 resolution or better which is common in professional video environments A touchscreen is not required but can be very useful The KSP software is included with the switcher application software Pur...

Page 29: ...Platform K2 M Series Turbo iDDR and T2 iDDR systems over Ethernet Odetics protocol for VTR control Serial and Ethernet VDCP Grass Valley Native Protocol for routers routing control systems Trinix Tri...

Page 30: ...14 Introduction Supported Control Protocols...

Page 31: ...ideo Processor Dimensions 15 RU Dimensions Front View CAUTION Mounting a GV K Frame X in a rack immediately below equipment that extends forward from the rack may not provide enough clearance to compl...

Page 32: ...16 Frame Installation 15 RU Video Processor Dimensions 15 RU Dimensions Side View...

Page 33: ...7 GV K Frame X Installation Planning Guide 15RU Video Processor Installation and Airflow 15 RU Rack Mounting and Cooling Airflow Air Intake Air Exhaust Air Exhaust Air Exhaust 8875_28 DO NOT BLOCK DOO...

Page 34: ...ws 15 RU Front View with Door Removed F6 IMAGE STORE F5 ME D1 D2 F4 ME C1 C2 F3 CONTROLLER ME F2 ME B1 B2 F1 ME A1 A2 8875_30 ME C1 C2 ME B1 B2 ME A1 A2 Image Store ME D1 D2 Controller with ME Fan Tra...

Page 35: ...OUT 49 56 R10 VID I O 9 IN 129 144 OUT 65 72 R9 VID I O 8 IN 113 128 OUT 57 64 R11 VID I O 10 IN 145 160 OUT 73 80 R12 MOD I O 1 IN M1 8 MEDIA PORT IN 1 OUT M1 4 R13 MOD I O 2 IN M9 16 MEDIA PORT IN...

Page 36: ...Frame Power Supply Frame Dimensions Front and Rear Views 482 mm 19 0 in Front View Cover Removed Front View with Cover Rear View 8875_11 44 mm 1 72 in 45 mm 1 8 in 79 mm 3 1 in 217 mm 8 5 in 38 mm 1 5...

Page 37: ...then supported by the lower chassis and eliminates the need for power supply rear rack supports In addition this placement allows removal of the GV K Frame X front door If the power supply frame is no...

Page 38: ...n Power Supply Cooling The top surface of the rear of the GV K Frame X Power Supply Frame has air holes and is slightly recessed which permits air flow even if equipment is mounted in the rack directl...

Page 39: ...ts instead of the more common C13 style to accommodate potentially higher currents Cables provided with GV K Frame X systems are matched to the destination country s standard For example in the USA C1...

Page 40: ...C power for the system which will result in the most reliable system possible Consider brown out Modern switching power supplies are constant power devices and as such unlike resistive loads the input...

Page 41: ...GV K Frame X system can be divided into two suites The Video Processor resources M Es eDPMs external devices etc can be assigned to each suite creating two switchers with one Video Processor Frame Eac...

Page 42: ...aseT 100BaseT 1000BaseT compatible Category 5 cable 8 conductor twisted pair The system will work at lower ratings with reduced performance 1000BaseT components are highly recommended Connectors RJ 45...

Page 43: ...Subnet Mask 255 255 255 0 Note 32 Crosspoint Remote Aux Panel default settings must be changed to operate with a GV K Frame X whose other components are configured with their default IP addresses All...

Page 44: ...om External Network Ethernet Serial Control Custom Multi Pin Menu 15m 50ft max length Custom Multi Pin Panel 15m 50ft max length Maintenance Only board front edge Panel Main LAN Panel Aux LAN not used...

Page 45: ...ing One PCU Using a second Kayenne PCU GV K Frame X suites can be located anywhere on the network permitting system control from different rooms floors or even different buildings 8877 08 Panel Main L...

Page 46: ...al Aux Stripe ME Stripe ME Stripe ME Stripe Suite Boundary Ethernet Custom Multi Pin Menu 15m 50ft max length Custom Multi Pin Panel 15m 50ft max length Ethernet 100m 300ft max single hop length unlim...

Page 47: ...o PCU Port 6 Internal Cabling The RJ 45 connectors inside the Satellite Panel trays are used for proprietary communications only Ethernet devices may be damaged if plugged into these connectors PCU Po...

Page 48: ...tem Communications Overview Suites and Control Surfaces The GV K Frame X Control Panel system flexibility allows you to locate control surfaces in physically separate locations Two dedicated customer...

Page 49: ...d through channels in the arm that have covers that snap into place 8875_37 Suite Boundary Ethernet Ethernet 100m 300ft max single hop length unlimited distance using switches Operator s Laptop Menu P...

Page 50: ...nt AC Power Sources 2 AC Power Source 8804_28 Touch Screen Menu Panel Bottom View Fanless PC Karrera Control Panel rear DVI D straight USB Type B PCU Connector OR To Switcher Network PC Power Input Gb...

Page 51: ...Input Output control are also available on the Frame Redundant AC Power Sources 2 Panel to Local Aux Control not Ethernet 8804_42_r1 Karrera Control Panel rear Karrera Local Aux Panel To Switcher Ethe...

Page 52: ...Switch 1 2 3 4 5 6 7 8 Remote Aux Panel Remote Aux Panel Clip Store Facility LAN Switch GV Korona Control Panel GV K Frame X Video Processor USB Keyboard VGA RS 232 RS 422 485 GPI In Out Tally Etherne...

Page 53: ...0 meters Multi mode Fiber Optic cabling with the 10GBASE SR Modules provided with the 10GE IP I O boards SDI Inputs and Outputs Inputs Non looping video inputs on the back of the Video Processor Frame...

Page 54: ...n of the looping input can be used either directly on the adjacent connector or at the end of a daisy chain looping to other equipment Analog Input Sync Rates will show Locked in the Frame Status pane...

Page 55: ...to the Nominal Switcher Delay A s plus the autotiming window range This value is the Maximum Switcher Delay value D s GV K Frame X System Timing 4 M E System Frame Operating Mode A Nominal Switcher De...

Page 56: ...ow will be properly timed throughout the system even if the signal is cascaded through multiple M Es The Switcher Horizontal and Switcher Vertical soft knobs adjust the timing of the GV K Frame X syst...

Page 57: ...Cabling The GV K Frame X system uses an Ethernet connection for communications with ClipStore Ethernet cables are connected from the Frame either directly or through a dedicated Ethernet switch to th...

Page 58: ...Store requires SDI connections for both video and key two connections In Out per channel for recording and playback For playback only two SDI connections to Out 1 and Out 2 are all that is required pe...

Page 59: ...s can be used to distribute GV K Frame X Aux Bus output The example shows DAs being used for both the Video and Key Aux Bus outputs from the frame Channel 2 Channel 3 Channel 4 Channel 1 Video Process...

Page 60: ...cification for each relay is 1A 60 V GPI and Relay Tally Connections Each GV K Frame X Video Input output module has a 37 pin female sub miniature D connector on the rear of the chassis available for...

Page 61: ...connector are connected to ground For applications that span across more than one connector only one ground common connection is required The following diagram has the GV K Frame X GPI inputs on the l...

Page 62: ...elay tally lamp system The last outputs have the common bus tied to ground this drives a logic system All relays can be used to drive logic or control external circuitry Relay Tally and GPI Output Con...

Page 63: ...r on the rear of the Frame Relay Tally and GPI Output Specifications Maximum current for any one output 1 amp AC DC Maximum current for any one common 2 amp AC DC Maximum off open circuit voltage betw...

Page 64: ...48 System Cabling GPI In GPI Out Relay Tally Pin Assignments Socket Pinout Pin 1 Pin 19 Pin 20 Pin 37 D 37 Female...

Page 65: ...15 8 Tally1A Tally17E Tally33I Tally49M Tally65Q 16 27 Tally2A Tally18E Tally34I Tally50MK Tally66Q 17 9 Tally3A Tally19E Tally35I Tally51M Tally67Q 18 28 Tally4A Tally20E Tally36I Tally52M Tally68Q 1...

Page 66: ...Out40 13 7 TallyComU TallyComY TallyComAC TallyComAG TallyComAK 14 26 TallyComU TallyComY TallyComAC TallyComAG TallyComAK 15 8 Tally81U Tally97Y Tally113AC Tally129AG Tally145AK 16 27 Tally82U Tally9...

Page 67: ...9AB Tally125AF Tally141AJ Tally157AN 34 36 Tally94X Tally110AB Tally126AF Tally142AJ Tally158AN 35 18 Tally95X Tally111AB Tally127AF Tally1 43AJ Tally159AN 36 37 Tally96X Tally112AB Tally128AF Tally14...

Page 68: ...ports present on all processor boards are also available for maintenance RS 232 Pinouts Socket Pin Signal 1 Chassis Ground 2 Transmit Data 3 Receive Data 4 Not used 5 Signal Ground 6 Not used 7 Clear...

Page 69: ...29 97 30 SMPTE RP211 Table 12 16 720p 50 59 94 60 SMPTE 296 Table 1 3 SD Modes 525i 29 97 SMPTE 259M 625i 25 SMPTE 259M Mechanical Component Depth Width Height Weighta a All weights are approximate Ra...

Page 70: ...ctors CAT5 UTP RJ45 connectors Max Cable Length 100m 300ft Note The GV K Frame X Video Processor has an internal Ethernet switch with six availableexternalports Oneconnection is required foreach Contr...

Page 71: ...0 Mbit s SMPTE 292M 1 485 Gbit s SMPTE 424M 2006 3 Gbit s Return loss 10 dB 1 5GHz to 3GHz Type of Connector 75 ohm BNC SMPTE 259M Nominal Amplitude 800mV peak to peak terminated Channel Coding Confor...

Page 72: ...v peak to peak across 75 ohm 10 Rise Fall Times 400 to 1400 picoseconds 75 ohm termination between 20 and 80 amplitude Timing Jitter I UI R 601 656 Alignment jitter 2 UI SD 1 UI HD Output Impedance 75...

Page 73: ...pment Canadian EMC Notice of Compliance This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the...

Page 74: ...ment this product may cause radio interference in which case the user may be required to take adequate measures This product has been evaluated and meets the following Safety Certification Standards C...

Page 75: ...000 3 3 Voltage Fluctuations Flicker EN 55022 Class A Conducted Emissions Radiated Magnetic Field Emissions Peak Inrush Current EN55103 2 2009 Electromagnetic compatibility Product family standard for...

Page 76: ......

Page 77: ...n a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail contact is also available from t...

Reviews: