5.12 Factory/Presets panel
Factory Section
Load Factory
: Clicking this button will restore the card to a factory
default state. Two checkboxes enable the user to choose whether
to include Parameters and/or Alarms in the restoration process
•
Note that User Presets are not changed
User Presets section
The ADX-1901 has memory registers which can hold up to 5 user-
defined parameter settings.
The
Current Preset
box (at the bottom left corner of the panel)
displays the last loaded preset. Any change to the card
configuration after a preset is loaded will change the display to
"Custom" instead of the preset value.
Select
any one of the five presets using the pull-down list.
Click
Load
to load the contents of the selected User Preset into
the ADX-1901. All parameter settings and values will be replaced
by the contents of the selected User Preset.
•
Click
Save
to store the current parameter settings and values
from the ADX-1901 into the selected User Preset. The existing
contents of the preset will be overwritten.
Profiles
This section provides the option to save and recover the entire card configuration (including user presets if desired) on
an external disk, or to copy it to another ADX-1901 card.
Click on
Profiles
to open the Profile Copy window.
Figure 5-27 Factory / Presets panel
Figure 5-28 Profile Copy window