16
Mounting Instruction MACH104
Release 07 07/2014
4
Technical data
General technical data
Dimensions
See “Dimension drawings” on page 17.
Weight
MACH104-20TX-F...
4.2 kg
MACH104-20TX-FR...
4.4 kg
MACH104-20TX-F-4PoE...
4.6 kg
Operating voltage Rated voltage range AC
100 V ... 240 V, 50 Hz ... 60 Hz
Voltage range AC incl.
maximum tolerances
90 V AC - 265 V AC, 47 Hz - 63 Hz
Current consump-
tion
Rated current for devices
without PoE
max. 0.3 A (240 V AC)
max. 0.5 A (100 V AC)
Rated current for devices with
PoE
max. 0.9 A (240 V AC)
max. 1.7 A (100 V AC)
Activation current
typ. <40 A at 265 V AC and cold start
PoE power
Maximum number of Powered
Devices (PDs)
This applies to the following device vari-
ants only:
MACH104-20TX-F-4PoE...
4 × Powered Device (PD) class 0 (15.4 W)
Power failure
bypass
> 12 ms (115 V AC)
Overload current
protection at input
Non-replaceable fuse
Climatic conditions
during operation
Ambient air temperature
a
.
a. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
+32 °F ... +122 °F (0 °C ... +50 °C)
Humidity
20 % ... 90 %
(non-condensing)
Air pressure
minimum 795 hPa (+9842 ft; +2000 m)
maximum 1060 hPa (
−
1312 ft;
−
400 m)
Climatic conditions
during storage
Ambient air temperature
b
.
b. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
−
4 °F ... +185 °F (
−
20 °C ...+85 °C)
Humidity
10 % ... 95 %
(non-condensing)
Air pressure
minimum 700 hPa (+9842 ft; +3000 m)
maximum 1060 hPa (
−
1312 ft;
−
400 m)
Signal contact
Switching current
max. 1 A, SELV
Switching voltage
max. 60 V DC or max. 30 V AC, SELV
Pollution degree
2
Protection classes Laser protection
Class 1 in compliance with IEC 60825-1
Degree of protection
IP 30
Summary of Contents for 942003002
Page 19: ...Mounting Instruction MACH104 Release 07 07 2014 19 ...
Page 20: ......