6.3 16DO module
6 Bit assignment of the process data
6.3.3 Assembly ID 102 (input data without diagnostic)
Input
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 0
X4-B
X4-A
X3-B
X3-A
X2-B
X2-A
X1-B
X1-A
Byte 1
X8-B
X8-A
X7-B
X7-A
X6-B
X6-A
X5-B
X5-A
Byte 2
MI-IME
0
0
0
MI-SCA
0
MI-LVA
MI-LVS
Table 62: Assembly ID 102 bit assignment
6.3.4 Key
D
X1-A…X8-A: Status, channel A (pin 4) of slots X1 to X8
D
X1-B…X8-B: Status, channel B (pin 2) of slots X1 to X8
D
MI-LVS: Module Info Byte – undervoltage system / sensor supply
D
MI-LVA: Module Info Byte – actuator undervoltage
D
MI-SCA: Module Info Byte – actuator short circuit
D
MI-IME: Module Info Byte – internal module error (error)
D
CE-X1A…CE-X8A: Channel error, channel A (pin 4) on slots X1 to X8
D
CE-X1B…CE-X8B: Channel error, channel B (pin 2) on slots X1 to X8