• The parts which have been sealed by the manufacturer should not be adjusted by the user.
• When the appliance is using LPG A LPG cylinder should be used.
• The LPG cylinder size: max diameter-350mm, max height-400mm.
• The appliance is to be installed with sufficient ventilation to prevent the occurrence of
unacceptable concentrations of substances harmful to health in the room in which the ap-
pliance is installed.
• The minimum distances between the appliance and adjacent walls is 0.5m.
• The hose for the appliance should not exceed 1.5m.
• The appliance should be installed in a suitably ventilated room. Permanent supply of fresh
air is ensured and there is no accumulation of unburned gases.
• The gas supply tubing or hose shall comply with the national requirements in force and
shall be periodically examined and replaced as necessary.
• The hose should comply with the standard EN16436. The regulator should comply with the
standard EN16129.
• The hose and regulator assembly may not be provided with the appliance in some regions.
• Check and suitably clean the inside of the oven before it is lit in order to avoid the emission
of fire from the oils that have accumulated during previous cooking.
• The burner outlets should be checked for obstruction during previous cooking.
• The burner outlets should be checked for obstruction and cleaned regularly with a soft
wire brush.
• It is necessary to avoid obstruction and to allow for a good combustion.
• The position of the connection flexible tube so as to ensure that it is not subjected to twis-
ting.
BEFORE LIGHTING
Inspect the gas supply hose prior to turning on the gas. If there is evidence of cut, wear or
abrasion, it must be replaced prior to use.
Screw the regulator onto the gas cylinder. Leak check the hose and regulator connections
with a soap and water solution before lighting the appliance.
LP GAS CYLINDER WARNING
1. Do not store spare liquid propane gas cylinder under or near this appliance.
2. Never fill the cylinder beyond 80 percent capacity.
3. Liquid propane cylinder must be fitted with an OVERFILL PROTECTION DEVICE (OPD).
4. If the information above is not followed exactly, a fire resulting in death or serious injury
may occur.
Summary of Contents for DIEGO P200X2
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ...1 FR Français 6 2 EN English 20 ...
Page 11: ...3 Insérez la plaque de cuisson en pierre 4 Raccordez le flexible de gaz au four ...
Page 16: ...6 ANOMALIES SOLUTIONS ...
Page 29: ...NOTE ...
Page 30: ...NOTE ...
Page 31: ......
Page 32: ......