TOP WHEEL
Mix and Match
1MANUL749
Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681
13
Specifications
Requirements
Physical
Tunnel space required
11
4”
(2.90 m)
Unit height
140”
(3.56 m)
Unit width
146”
(3.71 m)
Utility
Electrical
3 phase, 1HP / 0.75 kW motor standard
3 phase, 2HP / 1.5 kW motor for Brush Application
110V for Retract Option
Hydraulic
6 GPM @ 900 PSI
Pneumatic
0.3 CFM @ 90 PSI minimum 120 PSI maximum /
0.51 m
3
/h @ 620kPa minimum 827 kPa maximum
Water
(1) 3/4” hose @ 4
GPM @ 40 PSI / 19.05 mm @ 0.91 m
3
/h @ 275 kPa
Output
Physical
Vehicle clearance, height
90”
(2.29 m)
WARNING
–
DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE
SERVICING ANY EQUIPMENT!
CAUTION
–
IT IS RECOMMENDED THAT A LICENSED ELECTRICIAN IS
CONTRACTED TO PERFORM ALL ELECTRICAL INSTALLATIONS.
CAUTION
–
ALWAYS WEAR SAFETY GLASSES WHEN PERFORMING
MAINTENANCE ON ANY EQUIPMENT.
NOTE:
PNEUMATICS MAY NOT BE OPERATED WHEN PART OF insta-KLEEN
™
SYSTEM.
CAUTION
–
A COMPRESSED AIR SYSTEM SHOULD BE SET CORRECTLY TO
SUPPORT 90 PSI NECESSARY TO OPERATE EQUIPMENT BUT SHOULD NEVER
BE SET TO DELIVER MORE THAT 120 PSI AIR PRESSURE TO BELANGER®
SPECIFIED EQUIPMENT. FIELD SUPPLIED PNEUMATIC TUBING MUST HAVE A
MINIMUM OF 2 TIMES THE BURST STRENGTH OF SYSTEM PRESSURE.
NOTE:
YOUR HYDRAULIC SYSTEM MUST BE CAPABLE OF ADJUSTMENT TO
116 RPM
AT 900 PSI (62.1 BAR) WHILE LOADED AGAINST VEHICLE. PLEASE VERIFY
YOUR SYSTEMS CAPABILITY TO MEET THESE SETTINGS WHILE RUNNING A
VEHICLE PRIOR TO INSTALLING PIECE OF EQUIPMENT.