Operator Interface
M Bits
•
M500
→
ON = Rear push no treadle
•
M505
→
ON = Increase Rinse/Wax photo delays
•
M501
→
ON = Auto Roller enable
•
M506
→
NOT USED
•
M502
→
ON = Dryer with wash
•
M507
→
NOT USED
•
M503
→
ON = Photo-rinse direct
•
M508
→
NOT USED
•
M504
→
NOT USED
•
M509
→
NOT USED
Inputs
The inputs are on when terminal is driven to 0Vdc (sinking). When the input is on corresponding light on controller
will be on.
INPUT X0
→
Wash Enable
–
This input must be pulsed or held on to use wash. If not used it must be jumped out to
0Vdc. If pulsed on and back off the system will load only one car. When pulse on and Auto Roller enabled system
will automatically give Rollers.
Typically, this input is used by a POS system such as a wash card device.
INPUT X1
→
Treadle
–
This input must be off when vehicle not present. The input pulses on, then back off again
when a tire runs over the treadle. Not used if rear tire no treadle selected.
INPUT X2
→
Rinse/Wax Photo
–
This input must be on when vehicle not present. The input will turn off when
vehicle breaks photo beam.
INPUT X3
→
Roller Count (used only with conveyors)
–
This input must be on when not in use. The input pulses
off then back on again when Roller lifts trap door.
INPUT X4
→
Roller Recall (front tire pull only)
–
This input must be off when not in use. The input turns on when
Roller call button pressed. This input can only be used for calling another Roller if front tir
e didn’t catch first
Roller.
This is not a hot Roller input.
INPUT X5
→
Extra Function Photo
–
The input must be on when vehicle not present. The input will turn off when
vehicle breaks photo beam. Used to turn on added equipment between treadle and rinse photo eye. Use a light
operated photo eye to operate this input. Input may be tied to X2 if controlling additional rinse arch installed
immediately after arch controlled by rinse photo eye (Optional and not part of product offering)
INPUT X6
→
Load Photo
–
Input provided by Belanger for cus
tom systems that DON’T HAVE A CONVEYOR
. The
input must be on when vehicle not present. The input will turn off when vehicle breaks photo beam. (Optional and not
part of product offering). System will load a car into wash when the beam broke for .6 seconds. Will not be able to
load another car until beam remade for .6 seconds. Treadle must be removed when this input used. When used
make sure M500 and M501 are off, also set D140 and D141 to zero. No terminal provided; it must be wired directly
to the PLC X6.
INPUT X7
→
Hyd/Air Low-Level
–
Input must be on for Output 01 t
o function in “AUTO”.