Operation
Overview
The insta-
KLEEN™ is a drive through or conveyer fleet system. This equipment in this system is
electric driven not hydraulic except conveyer itself. It washes every vehicle without package or
option variations for fleet efficiency. It accommodates different cars drive through speeds because it
doesn’t track the cars position in the conventional manner. The system utilizes two sensing devices
to initiate, track, and reset washes as vehicles passes through. The wash could also be initiated by a
POS device.
insta-
KLEEN™ Control Center (ICC)
Component Overview
The ICC consists of the electrical enclosure, mounting frame, and water manifold assembly. It is
a cost affective fleet controller that uses time delays to save water and chemical. The system is
equipped with a user interface that allows the wash to be tweaked in for better chem./water
savings and change the loading style.
It’s provided with solid state, individual output modules.
Each output module has its own fuse and 3 position switch for ON/OFF/AUTO. This system can
control two zones of equipment, conveyor, Pre-soak arch, Rinse/wax arch, extra function,
dryers, and Titans.
Electrical Enclosure
The electrical enclosure houses the wash controls and motor starters for
electric drive equipment. All items inside this cabinet are to be serviced
by a licensed electrician.
Operator Interface
The operator interface is mounted into the face of the controller. It can be used to change two
types of settings D and M. D is a numerical value setting that can be adjusted up or down using
+ and
– keys. The unit of D is quantity or seconds. M is an ON/OFF setting used to enable or
disable a function.
Screen navigation
ESC key
– pressing the ESC key toggles screen between D setting screen and M setting
screen.
D Setting Screen
– This screen is used to change/display the settings of D140 to D155.
To navigate to among D140 to D155 press the OK key until data setting is not flashing then use
+ and
– keys to navigate.
To change data press OK key until data setting is flashing then use + and
– keys to increment
or decrement data set point.