Installation
DRYPOINT® RA 3-160
13
9.2
Installation plan
1
Air compressor
2
Aftercooler
3
Condensate separator
4
Prefilter
5
Bypass group
6
Dryer
7
Compressed-air tank
8
Final filter
9
Bekomat condensate drain
2
2
1
6
IN
OUT
7
- A -
- B -
1
7
5
6
IN
OUT
5
8
9
9
8
9
4
9
3
9
9
9
3
4
9
Installation
type A
is recommended when the compressor functions with reduced step switching and when the total
consumption corresponds to the throughput rate of the compressor.
Installation
type B
is recommended when the air consumption constantly varies, with peak values which considerably
exceed the throughput rate of the compressor. The storage capacity of the tank must be dimensioned in such a way
that a possible short-term high air demand (peak air consumption) can be compensated.
Note!
Contaminated intake air!
In the event that the intake air is strongly contaminated (ISO 8573.1 class 3.-3 or poorer quality), we
recommend the additional installation of a prefilter (e.g. CLEARPOINT F040), to avoid clogging of the
heat exchanger.