Beko BRH90CB User Manual Download Page 1

BRH90CB

EN

01M-9202173200-4121-01 

User Manual

Cooker Hood

Summary of Contents for BRH90CB

Page 1: ...BRH90CB EN 01M 9202173200 4121 01 User Manual Cooker Hood ...

Page 2: ...trolling the appliance 10 3 2 Efficient use in terms of energy saving 10 3 3 Operation of the hood 10 3 4 Replacement of lamp 11 3 5 Operation with flue connection 11 3 6 Operation without flue connection 11 4 Cleaning and maintenance 12 4 1 Cleaning of the grease filter 12 4 2 Replacement of carbon filters 12 5 Installation of appliance 13 5 1 Position of the appliance 13 5 2 Installation accesso...

Page 3: ...he user manual as well Follow the instructions by paying attention to all the information and warnings in the user manual Remember that this user manual may also apply to other models Differences between models are explicitly described in the manual Meanings of the Symbols Following symbols are used in various sections of this user manual C Important information and useful hints about usage A WARN...

Page 4: ...be used in household and similar applications such as Staff kitchen areas in shops offices and other working en vironments Farm houses By clients in hotels and other residentialtypeenvironments Bed and Breakfast type envi ronments Operate the appliance for its intended purpose only as de scribed in this manual The manufacturer cannot be held liable for damages result ing from improper installation...

Page 5: ... the appliance to the mains until the installation is fully complete Place the appliance in a way so that the plug is always accessible Do not touch the lamps if they have operated for a long time They can burn your hands since they will be hot Follow the regulations set out by competent authorities on dis charge of the exhaust air this warning is not applicable for use without flue Operate your a...

Page 6: ...h other non electric heating sources such as an open or combustion fireplace or gas water heaters for example The venting action of the range hood can create a low pressure maximum allowed negative pressure in this case is 4 Pa 0 04 mbar which can impede the standard venting operation of these other devices such as smoke up a chimney As such harmful fumes or low oxygen lev els can occur within the...

Page 7: ...r fuels including those in other rooms due to lack of back flow of com bustible gases These gases can potentially result in carbon mon oxide poisoning After installation of a range hood or other cooking fume extractor the operation of flued gas appliances should be tested by a competent person to ensure that back flow of com bustion gases do not occur 1 2 Compliance with the WEEE Directive and Dis...

Page 8: ... in the Directive 1 4 Package Information Packaging materials of the product are manufactured from recyclable materials in accordance with our National Environment Regulations Do not dis pose of the packaging materials together with the domestic or other wastes Take them to the pack aging material collection points designated by the local authorities 1 Important safety and environmental instructio...

Page 9: ...4 Control panel 5 Lighting 6 Grease filter 2 2 Technical data Model BRH90CB Supply voltage frequency 220 240V 50 Hz Lamp power 2x3 W Motor power 210 W Flow rate 3 Level 615 m h Insulation class of motor Class F Insulation class Class I 1 2 3 4 5 6 899 500 29 248 20 330 223 166 5 20 08 600 Mın848 Max1178 ...

Page 10: ...cient use in terms of energy saving When using your appliance adjust the speed settings according to vapour and odour intensity in order to save energy Use low speeds 1 2 under normal conditions and high speed 3 for intense odour and vapour The lamps on the hood are placed for illuminating the cooking area Using them for environmental lighting shall cause unnecessary energy expenditure and insuffi...

Page 11: ...s extracted through the flue duct which is fastened to the connection head on the hood The diameter of the flue duct must be the same as the connection ring In horizontal settings the pipe has to have a slight upward slope around 10º so that the air can exit the room easily 3 6 Operation without flue connection Air is filtered through the carbon filter and recirculated in the room Carbon filter is...

Page 12: ...ng out the steps specified above in reverse order This filter retains the oil particles in the air C You may wash your grease filters in the dishwasher A CAUTION In case of normal use clean your filter once in a month 4 2 Replacement of carbon filters Odour removing filters contain charcoal Active carbon Grease filters must be installed in the product regardless of whether or not charcoal filters ...

Page 13: ...or to assembly This distance should be 65 cm Distance must be measured from the surface of grate for gas cookers From surface of glass for electric cookers 5 2 Installation accessories 15 650mm Ürün Alt Yüzeyi 903 16 1 Product 2 Outer chimney 3 Inner chimney 4 Chimney connection plate 5 150 120mm adapter 6 Ø150mm plastic flue 7 User manual 8 4x Ø8mm plastic dowel 9 6x Ø6mm plastic dowel 10 4x 4 8x...

Page 14: ...er pipes in the close proximity of the drilling locations Figure 2 Draw a mid location line from the ceiling perpen dicular to the lower edge of the cooker hood Take the location line you drew as a reference and mark points A B C D E F G H I J according to the measurements in the assembly template Figure 1 Drill the marked points E F G H I J with Ø6mm drill and insert 6 Ø6mm plastic dowels in the ...

Page 15: ...mm plastic flue Fix the Ø120mm plastic flue adapter included in assembly accessories to the air baffle in the direc tion of the arrow Lock the flue adapter by turning it in the direction of the arrow Figure 6 Figure 5 Assemble the air baffle group with 3 9 x 22 screws from point G H I J that you have already prepared Figure 5 Figure 6 1 Aluminium air outlet pipe Assemble the 150 120 mm flue adapte...

Page 16: ...t on the product Connect the other end of the pipe to your flue Check that these two connections are tight enough so they will not come out when the appliance runs on full power Ensure that the flaps inside the flue work when tightened with clamp Connect the flue connection pipe outside the adapter Figure 8 a If the connection pipe is fitted inside the adapter the flue flaps that prevent air retur...

Page 17: ...ew Figure 9 5 6 Storage If you do not intend to use the appliance for a long time please store it carefully Please make sure that the appliance is un plugged cooled down and totally dry Store the appliance in a cool and dry place Keep the appliance out of the reach of children 5 7 Handling and transportation During handling and transportation carry the appliance in its original packaging The packa...

Page 18: ...n 220 and 240 V Illumination light does not operate Inspect the lamp switch Lamp switch shall be at on position Illumination light does not operate Inspect the lamps The lamps of the appliance shall il luminate Air inlet of the appliance is inad equate Inspect the grease filter Under normal operating conditions grease filter shall be cleaned at least once in a month Air inlet of the appliance is i...

Page 19: ...Arçelik A Ş Karaağaç Caddesi No 2 6 34445 Sütlüce İstanbul Türkiye www beko com ...