BLG15 C7S SERVICE MANUAL
Sensitivity: Public
3.8
Safety Switch (Door lock/Solenoid)
Picture 3.11 Safety switch
SOLENOID door safety lock was used. When a program is started after the door has
been closed, the SOLENOID door will be locked by sending a pulse for once through
the main board and it will be prevented from opening while the program is running.
Once the program has ended, the door lock will be opened by sending a pulse for once
through the main board.
Current of all components passes over the door safety lock. Machine will not work if it
is faulty.
Rated Operating Voltage : 230V 50-60Hz
Operating Current
: 16 A
Working Environment Humidity: Rh 10- 95%Rh
Working Environment Temperature
: 5°C / 75°C