BLG15 C7S SERVICE MANUAL
Sensitivity: Public
6.14
Interference Suppression Filter Installation/Removal
Remove the upper table.
Interference suppression filter cable terminals are removed.
2 screws at the back of the body attaching the terminal assembly to the body are
removed.
Remove the interference suppression filter from the cable tabs connected to the
terminal assembly and by unscrewing the plastic screw connected to the body.
Picture 6.95 Interference suppression filter installation/removal
6.15
Washing Motor
6.15.1 ATLAS motor
Picture 6.96 Motor Picture 6.97 Motor
Rear wall is removed. Poly V belt is removed.
Motor-Drum connection screws are removed (2 pieces).
Motor is connected to the drum at three points; 2 in the front and 1 in the back.
Power and communication connections are removed.
During installation, check if the rear connection and the rubber gasket on it are
seated well.