Bottom feed (with cylinder)
Via this parameter the differential feed is set.
Parameter 07:
Line 1
Number of stitches until the differential bottom feed
engages
Setting range:
0 - 2000
Parameter 08:
Fullness line 1 ON/ OFF
Setting range:
0 / 1
Parameter 09:
Line 2
Number of stitches how long the differential bottom
feed is engaged
Setting range:
0 - 2000
Parameter 10:
Fullness line 2 ON/ OFF
Setting range:
0 / 1
Parameter 11:
Line 3
Number of stitches how long the differential bottom
feed is engaged
Setting range:
0 - 2000
Parameter 12:
Fullness line 2 ON/ OFF
Setting range:
0 / 1
Bottom feed (with step motor)
Via this parameter the differential feed with step motor drive is set.
Parameter 07:
Line 1
Number of stitches
Setting range:
0 - 2000
Parameter 08:
Fullness in line 1
Setting range:
0 - 2000
Parameter 09:
Line 2
Number of stitches
Setting range:
0 - 2000
Parameter 10:
Fullness in line 2
Setting range:
0 - 2000
Parameter 11:
Line 3
Number of stitches
Setting range:
0 - 2000
Parameter 12:
Fullness in line 3
Setting range:
0 - 2000
24