3-23
4
Adjustments at the mitre knifes
4.1
Basic adjustment locked mitre knife
(seam end)
Between the mitre knife for the seam end and the basic
holder a distance (A) of 21 mm must be adjusted.
Loosen both screws (6 in this and in the picture at sec-
tion 4.2) and move the mitre knife axially. Tighten both
screws again.
4.2
Basic adjustment movable mitre
knife (seam start)
When the movable knife for seam start (1) has contact
to the locked mitre knife, the distance between both hol-
ders must be 3 mm.
Turn the screw of the magnet (2) in or out to adjust the
distance.
4.3
Mitre knife height
The height of the mitre knife pinoles (3) must be adju-
sted that they are in their lower position the distance (B)
of 6-7 mm higher than the holder of the mitre knifes.
Loosen the fixing screws (4) and move the pinoles (3)
axially. Tighten the screws again.
4.4
Mitre knife broadth
Turn the two screws (5 in the picture at section 4.2) until
the mitre knifes can be taken out.
Adjust the broadth (A) of the mitre knifes with the two
screws (1). At a seam distance of 12 mm, you will have
to adjust 10-10.2 mm here.
Now turn the two screws (2) as far until both knifes get
contact at their top.