background image

Foreword

Installation manual for T7BR

Foreword

All operator panels are developed to satisfy the demands of human-machine
communication. Built-in functions such as displaying and controlling text,
dynamic indication, time channels, alarm and recipe handling are included.
The operator panel works primarily in an object-oriented way, making it easy to
understand and use. Configuration is carried out on a PC using the iX Developer.
The project can then be transferred and stored in the operator panel itself.
Various types of automation equipment such as PLCs, servos or drives can be
connected to the operator panels. In this manual, the term “the controller” refers
to the connected equipment.
This manual explains how to install the operator panel. Please refer to the
iX Developer reference manual for further information.

Order no: MAEN185

Copyright © 2015-02 Beijer Electronics AB. All rights reserved.

The information in this document is subject to change without notice and is provided as available at the

time of printing. Beijer Electronics AB, including all its group companies, reserves the right to change any

information without updating this publication. Beijer Electronics AB, including all its group companies,

assumes no responsibility for any errors that may appear in this document. Read the entire installation

manual prior to installing and using this equipment. Only qualified personnel may install, operate or repair

this equipment. Beijer Electronics AB, including all its group companies, are not responsible for modified,

altered or renovated equipment. Because the equipment has a wide range of applications, users must acquire

the appropriate knowledge to use the equipment properly in their specific applications. Persons responsible

for the application and the equipment must themselves ensure that each application is in compliance with

all relevant requirements, standards and legislation in respect to configuration and safety. Only parts and

accessories manufactured according to specifications set by Beijer Electronics AB, including all its group

companies, may be used.

BEIJER ELECTRONICS AB, INCLUDING ALL ITS GROUP
COMPANIES, SHALL NOT BE LIABLE TO ANYONE FOR ANY
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING FROM THE INSTALLATION, USE OR
REPAIR OF THIS EQUIPMENT, WHETHER ARISING IN TORT,
CONTRACT, OR OTHERWISE. BUYER'S SOLE REMEDY SHALL
BE THE REPAIR, REPLACEMENT, OR REFUND OF PURCHASE
PRICE, AND THE CHOICE OF THE APPLICABLE REMEDY SHALL
BE AT THE SOLE DISCRETION OF BEIJER ELECTRONICS AB,
INCLUDING ALL ITS GROUP COMPANIES.

Beijer Electronics, MAEN185

Summary of Contents for T7BR

Page 1: ...T7BR Installation Manual English MAEN185 2015 02...

Page 2: ...roup companies assumes no responsibility for any errors that may appear in this document Read the entire installation manual prior to installing and using this equipment Only quali ed personnel may in...

Page 3: ...calData 13 4 ChemicalResistance 15 4 1 MetalCasing 15 4 2 Touch Screen and Overlay Material 16 4 2 1 Auto ex EB 16 4 2 2 Touch Screen Surface 17 4 2 3 Touch Screen Protector 17 4 3 Terminalto PanelGas...

Page 4: ...e open ush with plenty of water and get medical attention The gures in this manualserves an illustrative purpose Because of the many variables associated with any particular installation the supplier...

Page 5: ...Size TQ Lb In Phoenix Contact Part No 1757022 14 20 AWG 2 08 0 52 mm2 5 7 Warning Do not open when an explosive atmosphere is present N OUVREZ PAS SI UNE ATMOSPH REEXPLOSIVE EST PR SENTE Warning Expl...

Page 6: ...ompanyinginstallation instructions Onlyquali ed personnel may install the operatorpanel Separate the high voltage signal and supply cables Make sure that the voltage and polarity of the powersource is...

Page 7: ...e operatorpanel orparts thereofshall be recycledaccording to local regulations The followingcomponentscontain substancesthat might be hazardous tohealth and the environment lithiumbattery electrolytic...

Page 8: ...e Requirements Maximum installation plate thickness 7 mm Space requirements in millimeterswhen installingthe operatorpanel 100 204 100 100 50 143 50 mm Note The dimensions on the drawing are not propo...

Page 9: ...n the outline drawing Aseparate cut out drawingis available for download from the Beijer Electronics web site Formore information see sections Operator Panel Drawings and Technical Data 3 Installthe o...

Page 10: ...connecting it to the power outlet Ensure that the operator panel and the controller system have the same electrical grounding reference voltage level otherwise errors in communication may occur Ensur...

Page 11: ...take care to avoid static electricitythat could damage the panel 2 2 1 Connections to the Controller For information aboutthe cables to be used when connecting the operator panelto the controller ple...

Page 12: ...cables If USBcables are used attach themtothe cable relief brackets with the cable tiesprovided 2 2 3 Other Connections and Peripherals Cables peripheral equipment and accessories must be suitable fo...

Page 13: ...9 pin D sub contact with RS232 RTS CTS chassis mounted female with standard locking screws 4 40 UNC Communication module CAN Ethernet 1 10 100 Base T shielded RJ45 1 10 100 1000 Base T shielded RJ45 U...

Page 14: ...www beijerelectronics com UL approval Yes 61010 2 201 UL 508 replacement 1 See section Chemical Resistance for more information 2 Standby mode The backlight is turned off there are no cabled interface...

Page 15: ...llowing chemicals at room temperature Butanol Nitric acid 3 Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric acid 43 Sodium hypochlorite 10 Turpentine Note If exposure to any of the abo...

Page 16: ...SBP 60 95 1 Bleach 1 Hydrochloric acid 36 Sulfuric acid 10 Castor oil Linseed oil Tomato ketchup Caustic soda 40 1 Methanol Trichloroaceticacid 50 Cutting oil Nitric acid 10 White Spirit Cyclohexanol...

Page 17: ...out visible change Solvents Time Acetone 10 minutes Isopropanol 10 minutes Toluene 5 hours 4 2 3 Touch Screen Protector For harsh environments and exposure tooutdoorconditions it isrecommended to use...

Page 18: ...to the following chemicalsat room temperature Acetic acid conc Na hypochlorite 10 Ammonia 30 Nitric acid 10 Butanol Phosphoric acid 10 Ethyl acetate Phosphoric acid 20 Hydrochloric acid 37 cold Note...

Page 19: ...USB 2 USB Host 2 0 max output current 500 mA 5 Headphone Headphone Connector 6 LAN B 1 x 10 100 1000 Base T shielded RJ45 7 COM2 RS422 RS485 Communication Port 5 2 Communication Ports Serial port 9 pi...

Page 20: ...elDrawings 5 3 T7BR Outline mm 204 143 A 7 max 8 66 B 188 127 9 9 D C B A Connectors B OptionalCAN module not shown C USB host D SD memory card slot CAN depth doesnotexceed heatsink Beijer Electronics...

Page 21: ...o local electricalcodes between the quick connect terminalconnectoron the operatorpanel and the chassis of the panel see 2 in drawing above 2 Connect awire orgroundingbraid that is sized correctlyacco...

Page 22: ...5 RJ45 RJ45 RJ45 Industrial Ethernet Operator panel Operator panel Operator panel Operator panel Shielded Short and unshielded 0 1 F 250 V 1 1 3 3 8 8 2 2 In some industrialunits forEthernet the RJ45...

Page 23: ...n istobreak the shield see 3 in drawing above A more elegant methodistoexpand the shielded Ethernet cablingwith a piece of unshielded Ethernetcable see 4 in drawingabove The shield canbe grounded via...

Page 24: ...shield to the ground via a 0 1 F 250 V plastic capacitor Both ends are then connected tothe ground in terms ofHF but only connected to the ground at one end in terms ofLF thus avoidingthe 50 60 Hz gro...

Page 25: ...t in halfwith an 8 10 C increase in temperature A 15 20 C temperature increase results ina quarter ofthe lifespanetc Rittal has a goodprogram for estimatingthe anticipated average temperature in the c...

Page 26: ...LVaccording to EN 60950 protection against electric shock andUL 950 Note Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with 230 V AC relay cont...

Page 27: ...al Many peripherals includingUSBdevices bond the signal ground 0 V ofthe terminal to the protective earth ground Bondingsignal groundand protective earth ground may increase electrical emissions and i...

Page 28: ...the ground potential the shield should be connected tothe ground via 0 1 F 250 V plastic capacitorto preventground current in the braided shield A numberof manufacturers recommendthat the shield be g...

Page 29: ...Head office Beijer Electronics AB Box 426 201 24 Malm Sweden www beijerelectronics com 46 40 358600...