background image

Fundor T

4

The Fundor T centrifugal casting machine is
designed exclusively for casting dental alloys,
with the exception of titanium. 

 Any other use is

considered to be improper. We shall not be liable
for any damage resulting from improper use.

CAUTION! Titanium 

reacts very strongly to the

crucibles – personal injury and damage to the unit
are possible!

During melting, 

alloys containing beryllium

produce strong oxides that cause considerable wear
to the crucibles and remain there in significant
quantities. 

CAUTION!

 When beryllium is processed,

carcinogenic particles are released. Wear mouth
protection and ensure good suction extraction when
casting and finishing!

The safety instructions must be followed in order to
avoid personal injury or damage to equipment. We
shall not be liable for failure to comply with the
safety instructions.

General safety instructions

l

Place of use

The unit has been designed solely for use in dental
laboratories and comparable establishments for
research, commercial and training purposes. •
The unit may only be installed on an adequately
stable surface. • The unit must only be used in dry
rooms.

l

Operator and operating personnel

The unit must only be operated by dental
professionals, or they must provide supervision if
trainees or other persons operate unit. • Wear the
protective clothing prescribed for use in dental
laboratories and observe the rules of conduct. •
The unit may only be operated by staff members
who are familiar with and follow the instructions
of this operating manual. • The operating manual
must be easily accessible when the machine is
operated. • Observe the national accident
prevention regulations in addition to this operating
manual.

l

Handling the machine

Prior to connection to the power supply check
whether the specifications on the rating plate
correspond to the supply network. In the case
of uncertainty, consult an electrician. • The
unit is categorised under protection class 1
and may only be connected to properly earthed
power sources (earth contact sockets).  •
Modifications of the machine are not
permitted. • Always keep signs and stickers
such that they are easy to read. They must not
be removed. • Check the machine and leads
for damage regularly. The machine must not
be operated if it has any defects that may result
in risks for the employees or third persons. •
Protect the leads against heat, oil and sharp
edges. The leads must not be used to carry the
machine or to pull out the mains plug.

l

Care and maintenance

Always switch off the machine and pull out the
mains plug before performing care, cleaning
or maintenance work. • Only use dry or
slightly moist cloths for cleaning. Do not spray
the machine with water or immerse it in water.

l

Repairs

Repairs may be carried out solely by BEGO
customer service or by persons authorised by
BEGO customer service. • 

Metallic housings

must be grounded properly so as to prevent
them from carrying current. Otherwise they are
extremely dangerous because the housings
may be live due to damage to the machine!
Since a check to ensure that the housing is in a
de-energized state is mandatory every time the
machine has been opened (Germany: check in
accordance with DIN VDE 0701-1), only
qualified electricians may open the machine! •
Only BEGO replacement and wearing parts may
be used.

Safety instructions

Summary of Contents for Fundor T

Page 1: ...Fundor T BA 85 478 06 235 00227 English Translation of the original instructions ...

Page 2: ...g instructions must be read and understood before the device is used This particularly applies to the Safety information The warranty is void in cases of damage which is caused by non observance of the operating instructions We will also not accept liability for any resulting consequential damages Symbols used This symbol indicates very important information Failure to comply with it may result in...

Page 3: ...bout the unit Unit description 6 Scope of delivery Wearing parts and Extras 6 Technical data 6 Operation Installation 7 Working 8 Care 10 Problems Troubleshooting 11 Spare parts list Circuit diagram Certificate of conformity Labels and stickers Disposal advice Appendix ...

Page 4: ...be easily accessible when the machine is operated Observe the national accident prevention regulations in addition to this operating manual l Handling the machine Prior to connection to the power supply check whether the specifications on the rating plate correspond to the supply network In the case of uncertainty consult an electrician The unit is categorised under protection class 1 and may only...

Page 5: ...sary to note the safety an danger pecautions in the instructions for use when installind and starting of Multiplex and automatic gas lighter Working l The counterweight of the mould ist to be correctly adjusted in the clicking points in order to prevent the out of balace and so a moving of the machine when centrifugal casting Danger of burns due to hot parts l Wear protective clothing protective a...

Page 6: ...ption Scope of delivery Fundor T with double jointed arm 200 240 V 50 60 Hz ________ Order No 25025 100 120 V 50 60 Hz ________ Order No 25026 with 1 pack Auromelt HF melting powder 1 pair of safety goggles 2 feet accepting screw 3 crucibles for precious metal alloys 3 crucibles for cobalt chrome and non precious metal alloys 2 replacement tension springs for the centrifugal arm 2 replacement fuse...

Page 7: ... the right hand side panel and unscrew the two rubber feet Fasten the separately delivered feet and mark the fixing points at the bench Drill holes in the worktop and screw the casting machine down with suitable screw see figure 2 l Install the Multiplex melting torch next to the machine in a suitable position The automatic gas lighter facilities enormously the firing and adjustingof the melting t...

Page 8: ...e for some alloys 4 Turn the double jointed arm 8 counter clockwise so that the counterweight 9 stands at the right fig 4 5 Set the counterweight for the size of mould being used by raising the weight movingit and engaging it securely again Example for amould of size 3 approach the counterweight to the figure 3 If the counterweight is not se correctly the out of balace of the centrifugal armmay mo...

Page 9: ...n switch 2 Lamp Operation 3 Lamp Prepare 4 Lid 5 Switch for starting speed 6 Fuse 4 Amp 7 Fastening screws for automatic gas lighter 8 Double jointed arm 9 Counterweight 10 Crucible holder 11 Mould holder 12 Adjusting lever for mould height ...

Page 10: ...rior to inserting the alloy Danger of burns due to hot parts Carry out maintenance and cleaning work prior to casting or once the unit has cooled down CAUTION Switch off the unit and pull out the plug prior to any care or maintenance Working Important We recommend to use the following base socket moulds for metal mould rings only Base socket mould for metal mould ring size 3 Order no 52 627 Base s...

Page 11: ...d Wait approx 15 sec after having switched on After closing the lid casting wait approx 35 sec Centrifuging Prepare forgotten Put the calliper on Prepare does not function open the lid remelt the alloy fuses are defective Always first switch off the unit and pull out the plug Replace the fuses see pos 6 in fig 4 and or fig 1 Machine moves installation not correct See Installation when centrifuging...

Reviews: