1
Beghelli Canada Inc., 3900 14th Avenue, Markham, ON L3R 4R3 Tel: (905) 948-9500 Fax: (905) 948-8673
LED FLAT PANEL
Planex
®
PLNX
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
1. Do not let power cords touch hot surfaces.
2. Do not mount near gas or electric heaters.
3. Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering.
4. The use of accessory equipment not recommended by Beghelli, may cause an unsafe condition, and will void the warranty.
5. Do not use this equipment for other than its intended purpose.
6. Vapor barrier must be suitable for 90°C in formats 24-l2 [only required in Canada].
7. Minimum 90°C supply conductors.
8. Suitable for DAMP LOCATIONS.
9. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and
operation of the product and the hazards involved.
10. Servicing of this equipment should be performed by qualified service personnel.
SAVE THESE INSTRUCTIONS!
First make sure power is turned off before starting the installation!
Connect to VAC following wiring labels:
Connect VAC wires
Labels with indicate:
120-277VAC or
120-347VAC,
50-60Hz,
(black) Line/Hot,
(white) Neutral/Common
926000520
EACH MODEL NUMBER CONSISTS OF THE FOLLOWING:
SERIES / SIZE / COLOUR TEMP. / INPUT
SERIES:
PLNX
SIZE:
1 FT X 4 FT
2 FT X 2FT
2 FT X 4 FT
COLOUR TEMP.:
3500K, 4000K, 5000K
INPUT:
120-277VAC OR
120-347VAC,
50-60HZ
No user serviceable parts. Refer service to a qualified service
technician. Read instructions prior to installing and/or operating
this device. Installation should be performed by a licensed
electrician/installer in accordance with local codes.
INSTALLATION INSTRUCTIONS