background image

Installation and Technical Information

BEGA

Due to the dynamic nature of lighting products and the associated technologies, luminaire data on this sheet is subject to change at the discretion of BEGA North America. For the most current technical data, please refer to bega-us.com

BEGA   

1000 Bega Way, Carpinteria, CA 93013

   

(805)684-0533

   

© copyright BEGA 2020

Figure 1:

Overview:

LED Watts:

19.4W

System Watts: 24.0W
Controllability:

0-10V, TRIAC, and ELV dimmable

Weight:

10.1 lbs.

Protection Class: IP65

Tools Required:

•  4mm hex head screwdriver

•  6mm hex head screwdriver

 10

1

4

 39

3

4

 3

1

2

 27

1

4

 4

1

8

 7

1

2

 2

1

4

 60° 

 120° 

 180° 

 6

1

4

 1

3

4

-

84100

SURFACE WASHER FLOODLIGHT - 

OUTRIGGER ARM

11/12/2020

REV

PART NO.

SIZE

TYPE:

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY 

OF BEGA NORTH AMERICA, INC.

ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN 

PERMISSION OF BEGA NORTH AMERICA, INC. IS PROHIBITED.

DATE:

APPROVED:

P (805) 684-0533  -  www.bega-us.com

DESCRIPTION:

1000 BEGA Way, Carpinteria, California 93013

B

SHEET 1 OF 1

NOT TO SCALE

DATE

DESCRIPTION

CHANGED BY

REV

Surface washer floodlight - outrigger arm

84 100

Dimensions

A:

10-1/4”

B:

4-1/8”

C:

27-1/4”

D:

7-1/2”

Maintenance:

Clean regularly with solvent-free cleaner 

removing dirt and debris. Do not use high 

pressure cleaners.

Replacement Parts

See label inside of fixture for LED replacement 

part number.
Consult factory for all other replacement 

components.

Accessories

Please refer to the appropriate accessory installation 

sheet for further instruction when applicable.

 Updated: 11/16/20

84 100

1 of 2

C

D

B

A

Notice to Installer:

1. 

See page 2 for specific product safety warnings.

2.  In conformance with UL Standard 1598, a silicone based sealant must be used be-

tween luminaire and supporting surface.

3.  For ceiling and wall applications only. 

4. 

Luminaire mounts directly to finished surface over a standard vertical single gang wir

-

ing box (by others) 

84100 Installation:

1. 

Loosen the (4) 4mm hex screw on the fixture canopy to remove luminaire base.

2.  Feed luminaire wiring through the luminaire base into wiring box.

3.  Make supply wiring and luminaire wiring connections inside the wiring box: 

 

MAIN VOLTAGE SUPPLY WIRE TO BLACK LUMINAIRE WIRE 

 

NEUTRAL (COMMON) SUPPLY WIRE TO WHITE LUMINAIRE WIRE 

 

GREEN GROUND WIRE TO GREEN LUMINAIRE WIRE 

Dimming (if applicable): 

 

DIMMING CONTROL WIRE (+) TO POSITIVE DRIVER DIM CONTROL WIRE 

 

DIMMING CONTROL WIRE (-) TO NEGATIVE DRIVER DIM CONTROL WIRE

4.  Mount luminaire to ceiling or wall surface using appropriate hardware by others. Fix-

ture mounts directly to finished surface over recessed wiring box.  

5.  Place a small bead of silicone around the back side of the mounting plate that will 

come in contact with the finished surface (exterior applications only).

6.  Replace luminaire canopy (with luminaire attached) and tighten (4) 4mm hex head 

screws to secure into place.

7.  To adjust head angle, use 6mm hex key to loosen joint at the head and/or canopy of 

the fixture. Adjust as needed and re-tighten to fix in place. 