Replacement Parts

Accessories

Please refer to the appropriate

accessory installation sheet for

further instruction when applicable.

180° Glare Shield   

 

70 755

Elliptical Spread Lens 

 

70 050

77 756

LED compact floodlight - outrigger 

Tools Required:

4mm hex key

5mm hex key

Flat head screw driver medium

Phillips head screw driver medium

Protection Class: 

IP65

Weight:

 4.9 lbs

Dimensions

A:

    4-1/8 ”

B:

    27-1/2 ”

C:

    4-3/8 ”

D:

    7-1/2 x 3-1/2 “

Relamping/Mainten

ance

No relamping necessary.

Lamp:

   6.5W LED

    77 756

12/4/2017

Page 1 of 2

Description

Diffuser

Gasket

LED driver (120V-277V)

LED module (4000K)

Part No

140850

831652

75943

LED-0329/840

Notice to Installer for 77 756:

1. This product must be installed in accordance with the applicable installation code 

     by a person familiar with the construction and operation of the product and the 

     hazards involved. 

2. Mounts directly over a standard, vertical single gang wiring box (by others).

3. Ceiling and wall applications only.

4. In conformance with U.L. Standards 1598, a silicone-based sealant MUST be 

    used between the mounting plate edge and supporting wall.

5. 

WARNING: 

LEDs are high quality electrical components. Please avoid touching  

      

    them directly during installation.

77 756 - installation:

1. Loosen the (4) 4mm hex screw on the luminaire canopy and remove

    luminaire base from luminaire.

2. Feed luminaire wiring through the luminaire base and mounting plate.

3. Make supply wiring and luminaire wiring connections inside the wiring box:

 

MAIN VOLTAGE SUPPLY WIRE TO BLACK LUMINAIRE WIRE

 

NEUTRAL (COMMON) SUPPLY WIRE TO WHITE LUMINAIRE WIRE

 

GREEN GROUND WIRE TO GREEN LUMINAIRE WIRE

    Dimming (if applicable):

  

DIMMING CONTROL WIRE (+) TO POSITIVE DRIVER DIM CONTROL WIRE

  

DIMMING CONTROL WIRE (-) TO NEGATIVE DRIVER DIM CONTROL WIRE

4. Mount luminaire to ceiling or wall using hardware (by others). Minimum

    size: 8-32 screws

5. Replace luminaire canopy (with luminaire attached) and tighten (4) 4mm screws.

8. To adjust head angle, use 5mm hex key to loosen adjustment screw. Adjust

    luminaire head as needed and tighten adjustment screw.