BEGA 77 682 Installation And Technical Information Download Page 1

Installation and Technical Information

BEGA

In the interest of product improvement, BEGA reserves the right to make technical changes without notice.

Replacement Parts

Accessories

Please refer to the appropriate

accessory installation sheet for

further instruction when applicable.

180° Glare Shield   

70 755

Elliptical Spread Lens 

70 050

BEGA  

1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA-US 2017

Figure 1

Figure 2

Small scale floodlight with mounting canopy 

77 682

Tools Required:

5mm hex key

3mm hex key

Flat head screw driver medium

Phillips head screw driver medium

Protection Class: 

IP65

Weight:

  4.0 lbs.

Dimensions
A:

    5-1/2 ”

B:

    8 ”

C:

    5-1/2 ”

D:

    3-7/8 ”

Relamping/Maintenance

Remove trim and lens by loosening screws.  Clean 

luminaire and lens using only solvent-free cleansers.  

Replace trim and lens.  Tighten screws.

Lamp:

   13.9W LED Module

    77 682

7/10/2017

Page 1 of 2

Description

Lens

Lens gasket 

 

Driver

LED (4000K)

LED (3000K)

Part No

140851

831279

 

76097

LED-0623/940

LED-0623/930

Notice to Installer for 77 682:

1. See page 2 for specific product safety warnings.

2. Integral LED driver supplied by BEGA.

3. Luminaire mounts directly to standard recessed 4” octagonal wiring (by

    others), using mounting plate provided.

4. Do NOT remove moisture absorption packet from luminaire housing.

77 682 - installation:

1. Loosen the (1) 3mm hex screw on the luminaire canopy and remove

    luminaire base from luminaire.

2. Feed luminaire wiring through the luminaire base and mounting plate.

3. Make supply wiring and luminaire wiring connections inside the wiring box (by   

    others):

 

MAIN VOLTAGE SUPPLY WIRE TO BLACK LUMINAIRE WIRE

 

NEUTRAL (COMMON) SUPPLY WIRE TO WHITE LUMINAIRE WIRE

 

GREEN GROUND WIRE TO GREEN LUMINAIRE WIRE

    Dimming (if applicable):

 

DIMMING CONTROL WIRE (+) TO POSITIVE DRIVER DIM CONTROL  

 WIRE

 

DIMMING CONTROL WIRE (-) TO NEGATIVE DRIVER DIM CONTROL  

 WIRE

4. Attach provided mounting plate directly to a 4” standard octagonal wiring box

    using the (2) screws (provided).  Place a small bead of silicone around the back  

    side of the mounting plate that will come in contact with the finished surface        

    (exterior applications only).

5. Align and position mounting plate on mounting surface to correspond with  

   

    specified mounting orientation.  

6. Slip luminaire base over the mounting plate.  Tighten nuts on the studs  

     

    (provided) to secure.  

7. Replace luminaire canopy (with luminaire attached) and tighten (1) set screw.

8. To adjust head angle, use 5mm hex key to loosen adjustment screw. Adjust

    luminaire head as needed and tighten adjustment screw.