Installation and Technical Information
BEGA
Accessories
Please refer to the appropriate
accessory installation sheet for
further instruction when applicable.
In the interest of product improvement, BEGA reserves the right to make technical changes without notice.
Replacement Parts
BEGA
1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA-US 2019
Surface wall w/ cutoff optics
22 228
Tools Required:
3mm hex key
Standard medium screw driver
Phillips screw driver
Protection Class:
IP65
Weight:
1.5 lbs.
Dimensions
A:
4-3/4 ”
B:
4-3/4 ”
C:
2-3/4 ”
Relamping/Maintenance
Disassemble faceplate. Clean dirt and deposits from
the luminaire and glass using only solvent-free
cleaners. Relamp and replace gasket if damaged.
Reassemble faceplate.
Lamp:
3.0W LED 24V DC
22 228
01/31/2019
Page 1 of 2
Description
Faceplate
Gasket
LED Driver (24V DC)
LED Module (3000K)
LED Module (4000K)
Part No
FP2228
831032
75928
74038
74043
Notice to Installer for 22 228:
1. No relamping required.
2. In conformance with UL Standard 1598, a silicone based sealant must be used
between fixture and supporting wall.
3.
Requires a 24V DC class 2 electronic power supply to operate intended LED
wattage.
22 228 Installation:
1. Loosen the (3) M4 socket head screws on the luminaire top and remove top from
the luminaire base.
2. Loosen the (2) M4 socket head screws on the base to remove the electrical plate
from the base. However, keep the luminaire wiring routed through the wireway of
the luminaire base.
3. Attach the adaptor ring from the mounting kit to a 3-1/2” or 4” octagonal wiring box
using the (2) wiring box screws.
4. Make supply wiring and luminaire wiring connections inside the wiring box.
NEGATIVE SUPPLY WIRE TO BLACK LUMINAIRE WIRE
POSITIVE SUPPLY WIRE TO RED LUMINAIRE WIRE
5. Test to make sure the luminaire base will be level when installed by aligning the
mounting holes on the luminaire base with the holes in the adaptor ring. Adjust the
adaptor ring if needed.
6. Place a small bead of silicone around the back side of the luminaire flange that will
come in contact with the finished wall (exterior applications only).
7. Secure the luminaire base to the adaptor ring and finished wall by using the (2)
countersunk screws provided.
8. Replace electrical plate.
9. Replace luminaire top and tighten screws evenly
mounting
plate or
luminaire
base
adapter
plate
wiring
box
screws
3-1/2 or 4
standard
octagonal
wiring box
(by others)
mounting screws
Remote 25W LED driver and box
19 580
Remote 50W LED driver and box
19 591