background image

Installation and Technical Information

BEGA

Due to the dynamic nature of lighting products and the associated technologies, luminaire data on this sheet is subject to change at the discretion of BEGA North America. For the most current technical data, please refer to bega-us.com

BEGA   

1000 Bega Way, Carpinteria, CA 93013

   

(805)684-0533

   

© copyright BEGA 2019

Figure 1:

Figure 2:

Figure 3:

Overview:

System Watts: 2.4W
LED Watts:

2.1W

Controllability:

non dimmable

Weight:

0.5 lbs.

Protection Class: IP65

Tools Required:

• 3mm hex key

• 2.5mm hex key

Recessed wall luminaire  - Unshielded

22 202

Notice to Installer:

1.  BEGA luminaires may be damaged if connected to conduit systems containing 

water - Article 300-5G of National Electric Code requires that “Conduits or 

raceways through which moisture may contact energized live parts shall be sealed 

or plugged at either or both ends.”

2.  Luminaire is Non-IC rated. (Insulation must be at least 3” from luminaire)

3.  Suitable for through wiring: max. of (4) No. 12 AWG conductors (plus ground) rated 

for 90°C.

4.  Suitable for installation in hollow wall construction or poured concrete construction.

5.  Back housing provided with (2) 7/8” holes (horizontal entry) for 1/2” trade size 

conduit.

6. 

Back housing must be installed so that the front face is flush or slightly in front of 

finished wall.

7.  Wall applications only. (No ceiling and in-grade applications).

8.  Requires a remote 24V DC class 2 electronic power supply. (Not provided).

Backbox Installation: Hollow (stud) wall

1.  Install the (2) slotted mounting brackets [Figure 1], using the (2) #6-32 wing nuts in 

the installation kit. (Provided)

2.  Adjust the brackets (by loosening the #6-32 wing nuts) so that the face of the 

backbox mounts flush or slightly in front of finished wall surface.

3.  Secure the mounting brackets to wood or metal horizontal blocking, as shown in 

[Figure 2].

4.  Connect conduit to back housing and pull wires for wiring connections to be made 

later.

Backbox Installation: Poured concrete

1.  Attach (2) #8-32 threaded rods inside backbox. [Figure 3]

2.  Attach the backbox to the concrete form using the (2) wingnuts in the installation kit 

(Provided) [Figure 4].

3.  Connect conduit to back housing and pull wires for wiring connections. 

4.  Pour concrete.  

NOTE: DO NOT POUR CONCRETE DIRECTLY ON TOP OF THE BACK 

HOUSING.

5.  After concrete is set remove the wing nuts from threaded rod, remove form.

Inner Housing Installation: Luminaire Installation

1.  Undo (2) faceplate screws using 3mm hex key and carefully remove casting and 

lens from luminaire.

2.  Connect the luminaire to 24V DC supply wiring in backbox.

3.  Install inner housing into backbox, using a 2.5mm hex key tighten the (2) screws 

until housing is secure. 

4.  Place a small bead of silicone between the edge of backbox and wall to provide a 

seal.

5.  Re-install faceplate. Make sure that gasket and lens are seated properly.

6.  Tighten the (2) faceplate screws evenly to secure.

Dimensions
A:

3 1/8''

B:

3 1/8''

C:

3 7/8''

Due to the dynamic nature of lighting products and the associated technologies, luminaire data on this sheet is subject to change at the discretion of BEGA North America. For the most current technical data, please refer to bega-us.com

BEGA   

1000 Bega Way, Carpinteria, CA 93013

   

(805)684-0533

   

© copyright BEGA 2019

Maintenance:

Clean regularly with solvent-free cleaner 

removing dirt and debris. Do not use high 

pressure cleaners.

Replacement Parts

See label inside of fixture for LED replacement 

part number.
Consult factory for all other replacement 

components.

Accessories

Please refer to the appropriate accessory installation 

sheet for further instruction when applicable.
Remote 25W LED driver and box

19 580

Remote 50W LED driver and box

19 591