Product overview
EPP1xxx
50
Version: 1.4
Additional checks
The boxes have been subjected to the following checks:
Verification
Explanation
Vibration
10 frequency sweeps in 3 axes
5 Hz < f < 60 Hz displacement 0.35 mm, constant amplitude
60.1 Hz < f < 500 Hz acceleration 5 g, constant amplitude
Shocks
1000 shocks in each direction, in 3 axes
35 g, 11 ms
3.12.2.1
Acceleration measurement
Technical data
Acceleration measurement
Inclination measurement
Raw values
Measured values
Measuring range
1)
Adjustable:
• ±2 g
• ±4 g
• ±8 g
• ±16 g
±180°
Resolution
1)
10-bit
• Measuring range ±2 g: 4 mg
• Measuring range ±4 g: 8 mg
• Measuring range ±8 g: 16 mg
• Measuring range ±16 g: 48 mg
1°
Representation
1)
10-bit in 16-bit
(left aligned)
1 mg / LSB
1° / LSB
Sampling rate
1 … 5000 Hz
1)
Unit of measurement: 1 g = 9.81 m/s
2
(acceleration of gravity). 1 mg = 1/1000 g