Index 6000 DO Inputs Ch.1
Index
Name
Meaning
Data type
Flags Default
6000:0
DO Inputs Ch.1
UINT8
RO
0x0E (14
dec
)
6000:01
Input 1
boolean
RO
0x00 (0
dec
)
6000:02
Input 2
boolean
RO
0x00 (0
dec
)
6000:03
Input 3
boolean
RO
0x00 (0
dec
)
6000:04
Input 4
boolean
RO
0x00 (0
dec
)
6000:05
Input 5
boolean
RO
0x00 (0
dec
)
6000:06
Input 6
boolean
RO
0x00 (0
dec
)
6000:07
Input 7
boolean
RO
0x00 (0
dec
)
6000:08
Input 8
boolean
RO
0x00 (0
dec
)
6000:0E
Sync Error
boolean
RO
0x00 (0
dec
)
Index 6010 DO Inputs Ch.2
Index
Name
Meaning
Data type
Flags Default
6010:0
DO Inputs Ch.2
UINT8
RO
0x0E (14
dec
)
6010:01
Input 1
boolean
RO
0x00 (0
dec
)
6010:02
Input 2
boolean
RO
0x00 (0
dec
)
6010:03
Input 3
boolean
RO
0x00 (0
dec
)
6010:04
Input 4
boolean
RO
0x00 (0
dec
)
6010:05
Input 5
boolean
RO
0x00 (0
dec
)
6010:06
Input 6
boolean
RO
0x00 (0
dec
)
6010:07
Input 7
boolean
RO
0x00 (0
dec
)
6010:08
Input 8
boolean
RO
0x00 (0
dec
)
6010:0E
Sync Error
boolean
RO
0x00 (0
dec
)
Index F000 Modular device profile
Index
Name
Meaning
Data type
Flags Default
F000:0
Modular device
profile
General information for the modular device profile
UINT8
RO
0x02 (2
dec
)
F000:01
Module index
distance
Index distance of the objects of the individual channels
UINT16
RO
0x0010 (16
dec
)
F000:02
Maximum num-
ber of modules
Number of channels
UINT16
RO
0x0002 (2
dec
)
Index F008 Code word
Index
Name
Meaning
Data type
Flags Default
F008:0
Code word
UINT32
RW
0x00000000 (0
dec
)
Index F010 Module list
Index
Name
Meaning
Data type
Flags Default
F010:0
Module list
UINT8
RW
0x02 (2
dec
)
F010:01
SubIndex 001
UINT32
RW
0x00000118 (280
dec
)
F010:02
SubIndex 002
UINT32
RW
0x00000118 (280
dec
)