Commissioning
EL6692
114
Version: 3.2
• Execute "Get configuration" on the secondary side; see the fig. "
Get configuration" on the secondary
side.
The process data configured on the primary side are generated accordingly in the configuration
tree.
Fig. 140: "Create configuration" on the primary side
Fig. 141: "Get configuration" on the secondary side
The CoE folders of both halves of the EL6692 are used to save the process data configuration in the
EL6692. The types and complexity of the definable process data are therefore limited. If the notes from the
fig. "
Get configuration" on the secondary side
are displayed during the "Create Configuration" procedure, the