Interface description
CX20x3
20
Version: 1.0
5.4
Optional interfaces
An optional interface is an additional interface that can be equipped with a wide range of signal types ex
factory and extends the Embedded PC beyond the basic equipment. The optional interface must be ordered
in advance and cannot be retrofitted to the device.
5.4.1
DVI-D (N010)
The DVI-D interface (X300) transfers digital data and is suitable for connection to digital displays. If the
optional N010 interface (DVI-D interface) is used, the first DVI-I interface can be operated either in VGA
mode or in DVI mode. The resolution at the display or the Beckhoff Control Panel depends on the distance
from the display device. The maximum distance is 5 m. Beckhoff offers various Panels with an integrated
“DVI extension”. These make a cable length of up to 50 meters possible.
Fig. 7: DVI-D interface X300.
Table 11: DVI-D interface X300, pin assignment.
Pin
Connection
Pin
Connection
Pin
Connection
1
TMDS Data 2-
9
TMDS Data 1-
17
TMDS Data 0-
2
TMDS Data 2+
10
TMDS Data 1+
18
TMDS Data 0+
3
TMDS Data 2/4 Shield
11
TMDS Data 1/3 Shield
19
TMDS Data 0/5 Shield
4
not connected
12
not connected
20
not connected
5
not connected
13
not connected
21
not connected
6
DDC Clock
14
+ 5V Power
22
TMDS Clock Shield
7
DDC Data
15
Ground ( +5V, Analog H/
V Sync)
23
TMDS Clock +
8
Analog Vertical Sync
16
Hot Plug Detect
24
TMDA Clock -
Table 12: DVI-D interface X300, resolution at the monitor.
Resolution in pixels
Distance of the interface from the monitor
1920 x 1200
5 m
1920 x 1080
5 m
1600 x 1200
5 m
1280 x 1024
5 m
1024 x 768
5 m
800 x 600
5 m
640 x 480
5 m
The Embedded PC also supports higher resolutions, based on the DVI standard. A maximum resolution of
2560 x 1440 pixels can be set on the Embedded PC. Whether this resolution is achieved depends on the
monitor, the cable quality and the cable length.