Shutting down
CP29xx
37
Version: 3.1
5.2
Disassembly and disposal
Removal from the control cabinet
Before you can remove the Control Panel from the control cabinet, you must first disconnect the power
supply and the cables (see Chapter 5.1
Disconnecting the power supply and cables [
To remove the Control Panel from the control cabinet, follow the steps shown in Fig. 20:
1. Loosen the clamping levers with a 3.0 mm Allen key (sections A and B).
2. Fold the clamping levers back by 90° onto the housing (section C).
ð
You can now remove the Panel from the control cabinet.
3. To reattach the clamping levers to the housing, retighten them with the Allen key (section D).
D
C
B
A
Fig. 20: CP29xx_Removal from the control cabinet
Disposal of the Control Panel
When disposing of the Control Panel the national electronic waste regulations must be followed.
For disposal, you must remove the device from the control cabinet.