background image

Technical data

CP22xx

47

Version: 2.0

9

Technical data

Table 14: Technical data

Product designation

CP22xx

Weight

CP2212: 5.2 kg

CP2213: 5.2 kg

CP2215: 5.9 kg

CP2216: 6.7 kg

CP2218: 7.5 kg

CP2219: 7.8 kg

CP2221: 8.3 kg

CP2224: 9.6 kg

Supply voltage

20.4-30 V

DC

 (24 V

DC

 power supply unit, NEC class 2)

Maximum power consumption with
basic configuration

1)

CP2212: approx. 58 W

CP2213: approx. 53 W

CP2215: approx. 62 W

CP2216: approx. 55 W

CP2218: approx. 67 W

CP2219: approx. 67 W

CP2221: approx. 69 W

CP2224: approx. 76 W

Protection rating

Front IP65, rear IP20

Vibration resistance (sinusoidal
vibration)

EN 60068-2-6:

10 ... 58 Hz:

0.035 mm

58 ... 500 Hz:

0.5 G (~ 5 m/ s

2

)

Shock resistance (shock)

EN 60068-2-27:

5 G (~ 50 m/ s

2

), duration: 30 ms

EMC interference immunity

conforms to EN 61000-6-2

EMC interference emission

conforms to EN 61000-6-4

Permissible ambient temperature

Operation: 0 °C to +55 °C

Transport / storage: -25 °C to +65 °C

Permissible relative air humidity

Maximum 95%, no condensation

Transport and storage

The same values for air humidity and shock resistance are to be
observed during transport and storage as in operation. The shock
resistance during transport can be improved by means of suitably
packing the Panel PC.

1)

The power consumption of your device beyond the basic configuration can be found in the data sheet

Power loss and power consumption. There you will find information on how the power consumption of your
device changes according to the selected equipment, accessories and connected devices.

Summary of Contents for CP22 Series

Page 1: ...Manual EN CP22xx Panel PC 2022 7 26 Version 2 0...

Page 2: ......

Page 3: ...4 Name plate 19 4 Commissioning 21 4 1 Transport and unpacking 22 4 2 Control cabinet installation 23 4 3 Connecting the Panel PC 25 4 3 1 Mounting power supply cable 26 4 3 2 Grounding the Panel PC...

Page 4: ...Table of contents CP22xx 4 Version 2 0...

Page 5: ...The configurations depicted may deviate from the standard Trademarks Beckhoff TwinCAT TwinCAT BSD TC BSD EtherCAT EtherCAT G EtherCAT G10 EtherCAT P Safety over EtherCAT TwinSAFE XFC XTS and XPlanar a...

Page 6: ...lead to minor injuries Warning of damage to property NOTE Disregarding the notice may lead to damage to property 2 2 Intended use The Panel PC is designed for installation in the front of a control ca...

Page 7: ...ed specialists with a control and automation engineering background operate the device Use by unauthorized persons can lead to damage to property and loss of data Fuse the power supply line to protect...

Page 8: ...rks The latter should be connected to the corporate network or the Internet only if appropriate protective measures have been set up In addition the recommendations from Beckhoff regarding appropriate...

Page 9: ...19 inch 1280 x 1024 21 5 inch 1920 x 1080 24 inch 1920 x 1080 The device has a multi finger touch screen and an aluminum housing with glass front with IP65 on the front side and IP20 on the rear side...

Page 10: ...Product overview CP22xx 10 Version 2 0 1 2 Fig 1 CP22xx_without and with push button extension...

Page 11: ...nt Description 1 Clamping lever Mounting the Panel PC in the panel of the control cabinet 2 Access to storage media Storage media behind the cover 3 Fan access Fan cartridges 4 Access battery Battery...

Page 12: ...terfaces Power supply X110 Ethernet RJ45 X109 X108 USB X104 X107 DVI X103 RS232 X102 The interfaces are located on the rear side of the Panel PC at the bottom in the connection section Depending on th...

Page 13: ...pole of the battery pack 2 BAT Positive pole of the battery pack 3 27 V UPS 27 V UPS output 2 5 A negative is pin 1 BAT 4 Protective earth 5 Negative pole Supply voltage 24 V 6 24 V Positive pole Sup...

Page 14: ...pplications with EtherCAT The Ethernet port X108 LAN1 integrated in the chipset with the i219 controller is generally suitable for EtherCAT and Real Time Ethernet applications with cycle times 1 ms wi...

Page 15: ...ct peripheral devices with USB interfaces 9 8 7 5 6 1 2 3 4 1 2 3 4 9 8 7 6 5 9 8 7 6 5 1 2 3 4 9 8 7 6 5 1 2 3 4 X104 X105 X106 X107 Fig 6 CP22xx_USB port pin numbering Table 4 USB interface pin assi...

Page 16: ...nected 21 not connected 6 DDC Clock 14 5V Power 22 TDMS Clock Shield 7 DDC Data 15 Ground 5 V Analog H V Sync 23 TDMS Clock 8 Analog Vertical Sync 16 Hot Plug Detect 24 TDMA Clock C5 GND 3 2 5 RS232 T...

Page 17: ...9 pin Configuration as endpoint without echo Echo off Auto send on Always send off Auto receive on Always receive off Termination on CP22xx 0030 C9900 E242 Serial interface COM2 RS485 electrical isola...

Page 18: ...s of the module slots with the ordered PCIe modules on your own Regardless of where the module slots are located you must proceed in the same way To do this loosen the two M3x4 screws of the covers in...

Page 19: ...er BTN 3 Date of manufacture 4 Mainboard 5 CPU 6 Storage media 7 Power supply 8 Main memory 9 Storage media 10 Display 11 Touch screen 12 Optional interface X101 13 Optional slots for PCIe compact mod...

Page 20: ...ble to the device such as CE EAC UKCA The approvals of your device can be found on the name plate and in chapter 10 2 Approvals 49 24 Address of the vendor 25 Access to motherboard battery 26 Access t...

Page 21: ...gainst dirt and scratching for example due to dirty hands this can be achieved with a Beckhoff protective film The film provides short term protection for a few days You can either order your device d...

Page 22: ...he device Protect the device against moisture condensation during transport in cold weather or in case of ex treme temperature fluctuations Do not put the device into operation until it has slowly adj...

Page 23: ...imensions of the Panel PC The wall thickness must be between 1 mm and 5 mm for installation After installation be sure to check the tightness between the Panel PC and the built in wall Please also not...

Page 24: ...nel PC at the intended position in the panel of the control cabinet Make sure that the device is secured against falling out until it is fastened properly Fig 13 CP22xx_wall positioning 2 Fold out the...

Page 25: ...ly unit is required to supply 24 V DC 15 20 for operating the device The cabling of the Panel PC in the control cabinet must be done in accordance with the standard EN 60204 1 2006 PELV Protective Ext...

Page 26: ...th the ferrules into the 8 pin connection strip For the pin assignment of the connector see Chapter 3 2 1 Power supply 13 5 Screw the cable ends into the 8 pin connection strip You have mounted the pl...

Page 27: ...Commissioning CP22xx 27 Version 2 0 Fig 16 CP22xx_disassembly the strain relief housing...

Page 28: ...se of the Panel PC without a functional earth can lead to material damage due to electromagnetic in terference Only use the device with functional earth Electromagnetic compatibility EMC of the Panel...

Page 29: ...the voltage connector into the voltage socket on the Panel PC 3 Screw the voltage connector to the voltage socket 4 Connect the PC to your external 24 V power supply 5 Switch on the 24 V power supply...

Page 30: ...30 V 9 A C9900 U330 battery pack 3 4 5 1 2 3 4 5 6 7 8 Battery 24 V Power 24 V DC UPS PC_ON Power status Industrial PC power connector L max 10 m 1 5 mm AWG14 2 0 V 24 V DC UPS Output X1 X2 Power sta...

Page 31: ...ery With daily use this significantly shortens the life of the battery Avoid switching off the power supply before shutting down the operating system Use the Beckhoff concept see below to shut down th...

Page 32: ...ave to install them yourself In this case contact Beckhoff Service who will provide you with software and drivers The driver software comes with a detailed help function Call up the help files either...

Page 33: ...using the Beckhoff Device Manager to remotely configure the Industrial PC via a web browser More detailed information is available in the Beckhoff Device Manager manual First start Beckhoff Device Man...

Page 34: ...words are an important prerequisite for a secure system Beckhoff supplies the device images with standard user names and standard passwords for the operating system It is imperative that you change th...

Page 35: ...connecting the Panel PC during a thunderstorm can lead to electric shock Never disconnect the cables of the Panel PC during a thunderstorm Before removing the Panel PC follow the steps below 1 Shut do...

Page 36: ...ping levers with a 3 0 mm Allen key sections A and B Make sure that the device is secured against falling out until it is removed from the wall 2 Fold the clamping levers back by 90 onto the housing s...

Page 37: ...tain an ambient temperature range of 0 C to 55 C Cleaning agents In order to avoid damage to the front of the Panel PC during cleaning you must use suitable cleaning agents Examples include benzine sp...

Page 38: ...ered from Beckhoff Service Beckhoff Panel PCs are manufactured from components of the highest quality and robustness They are selected and tested for best interoperability long term availability and r...

Page 39: ...und and charging is prevented An ESD protected environment can best be created by setting up ESD protection zones The following measures serve this purpose ESD compliant floors with sufficient conduct...

Page 40: ...Scratches on the motherboard may cause the motherboard to fail Be very careful when replacing the battery and be sure to avoid scratches on the motherboard The Panel PC does not contain a lithium ion...

Page 41: ...use it to back up the operating system You can then restore the images created in this way The BST is available on a bootable BST USB flash drive This includes Windows and a backup software Select th...

Page 42: ...n Fig 28 1 Loosen and remove the M4 screw section A 2 Fold the cover to the left side section B 3 Press lightly on the CFast from above like on a button section C When you release the CFast the push p...

Page 43: ...Maintenance CP22xx 43 Version 2 0 A B C D Fig 28 CP22xx_exchange CFast The old storage media must be disposed of in accordance with the national electronic waste regulations...

Page 44: ...Service see Chapter 10 1 Service and Support 48 You can replace the fan cartridges while the PC is running Insert the new cartridge immediately after removing the old one To replace the fan cartridges...

Page 45: ...Maintenance CP22xx 45 Version 2 0 The old fan cartridges must be disposed of in accordance with the national electronic scrap regulation...

Page 46: ...roperly The cause of the error is the software or plant parts outside of the Panel PC Call the machine or software manufacturer The Panel PC only works partially or only temporarily e g dark image or...

Page 47: ...k resistance shock EN 60068 2 27 5 G 50 m s2 duration 30 ms EMC interference immunity conforms to EN 61000 6 2 EMC interference emission conforms to EN 61000 6 4 Permissible ambient temperature Operat...

Page 48: ...be found on the name plate Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ra...

Page 49: ...regulations These limits are designed to provide adequate protection against adverse interference if the device is used in a commercial environment This device generates uses and may emit radio freque...

Page 50: ...g lever 23 Fig 13 CP22xx_wall positioning 24 Fig 14 CP22xx_control cabinet installation 24 Fig 15 CP22xx_assembly of strain relief housing 26 Fig 16 CP22xx_disassembly the strain relief housing 27 Fig...

Page 51: ...15 Table 5 DVI interface pin assignment 16 Table 6 RS232 pin assignment 16 Table 7 CP22xx interface options 17 Table 8 CP22xx PCIe module slots 17 Table 9 Key CP22xx name plate 19 Table 10 Order iden...

Page 52: ......