LED’s
CB6464
30
Version: 0.4
8
LED’s
8.1
LED: Powercontroller
There is a RGB LED on the board with which status messages of the power controller are output by means
of colors and flashing intervals.
Fig. 9: CB6464 PWRCTRL-LED
Color
Interval
Meaning
None
Steadily lit
System in error state
White
Steadily lit
Power fail
Cyan
Steadily lit
Reserved
Magenta
Steadily lit
S UPS active (if existent)
Blue
Steadily lit
Reserved
Yellow
Steadily lit
S5 state
Green
Steadily lit
S0 state
Red
Steadily lit
Reset/Start
Green/yellow
Flashing
Bootloader running without error
Red/yellow
Flashing
Bootloader is starting (start sequence is being run
through)
Yellow
Flashing (6s)
S4 state
Yellow
Flashing (3s)
S3 state
Magenta
Flashing (0,5s)
S UPS capacitance test (if S UPS exists)
Red/magenta
Flashing
Checksum error during the I2C transmission in the
bootloader
A steadily lit red LED can indicate a hardware error.
Adaptation of the status codes
It is possible to adapt the status codes (e.g. as TwinCAT LED). To do this, the system colors can be
changed with the aid of an SMB command. This change remains in force until the next restart or re-
set. A change of the default colors is indicated by the additional flashing of the white LED.
Summary of Contents for CB6464
Page 1: ...Manual for Computerboard CB6464 0 4 25 10 2019 Version Date...
Page 2: ......
Page 6: ...CB6464 6 Version 0 4...
Page 64: ...Mechanical drawings CB6464 64 Version 0 4 10 2 PCB Pin 1 distances Fig 14 MZ Pin1 CB6464_G3...
Page 65: ...Mechanical drawings CB6464 65 Version 0 4 10 3 PCB Dimensions Fig 15 MZ CB6464_G3...