4.10.1
Connection to a stepper motor controller with 5V signal level (X4)
You can use this interface to connect the servo amplifier to a stepper motor control with a
5V signal level. The SubD connector X4 is used for this purpose.
Limit frequency: 1 MHz
AGND (terminal X3/1) must be connected to the ground of the control system!
4.10.2
Connection to a stepper motor controller with 24V signal level (X3)
You can use this interface to connect the servo amplifier to a stepper motor control with a
24V signal level. The digital inputs DIGITAL-IN 1 and 2 on connector X3 are used for this
purpose.
Limit frequency: 100 kHz
AGND (terminal X3/1) must be connected to the ground of the control system!