![Beckhoff AM3000 Series Operating Instructions Manual Download Page 22](http://html1.mh-extra.com/html/beckhoff/am3000-series/am3000-series_operating-instructions-manual_2719348022.webp)
Electrical installation
Synchronous servomotor
22
Version: 2.1
8.2
Connection of motors with preassembled cables
Beckhoff offers preassembled motor and feedback cables for safe, faster and flawless installation of the
motors. Beckhoff cables have been tested with regard to the materials, shielding and connectors used. They
ensure proper functioning and compliance with statutory regulations such as EMC, UL etc. The use of other
cables may lead to unexpected interference and invalidate the warranty.
• Carry out the wiring in accordance with the valid standards and regulations.
• Only use our preassembled shielded cables for the power and feedback connections.
• Connect up the shielding according to the wiring diagrams in section shielding according. Incorrectly
installed shielding inevitably leads to EMC interference.
Detailed specifications of the cables can be found on our homepage under
Download→ Documentation→ Drive Technology→ Cables.