Maintenance and cleaning
84
───
Version: 2.1
AG2400
10.2
Intervals
Under nominal conditions, the motor components have different op-
erating hours. We have provided you with a list of maintenance work
and intervals for the associated components below:
Component
Interval
Maintenance
Gear unit
During commissioning
Thereafter:
Every three months
Check gear unit for external damage and leaks
Check drive shaft and output shaft for foreign media such as oil
and dirt
Check gear unit for corrosion
Clamping screw
Motor attachment
During commissioning
Thereafter:
Every three months
Check tightening torques
Fastening screw
Gear unit housing
During commissioning
Thereafter:
Every three months
Check tightening torques
10.2.1
Lubrication
Notes on lubrication
Beckhoff gear units from the AG2400 series are lubricated for life.
The lubricant used does not have to be renewed.
If you wish to change the lubricant, contact Beckhoff Service.
All gear units are lubricated for life in the factory with a synthetic
polyglycol gear oil or with a high-performance grease.
Refer to the name plate for detailed information on lubrication. All
bearings are lubricated for life at the factory.
Further information on the lubricants can be obtained directly from
the manufacturer.
Summary of Contents for AG2400
Page 2: ......
Page 33: ...Technical data Version 2 1 33 AG2400 Clamping hub diameter up to G 24 mm...
Page 40: ...Technical data 40 Version 2 1 AG2400 Clamping hub diameter up to K 38 mm...
Page 42: ...Technical data 42 Version 2 1 AG2400 Clamping hub diameter up to G 24 mm...
Page 49: ...Technical data Version 2 1 49 AG2400 Clamping hub diameter up to C 14 mm...
Page 56: ...Technical data 56 Version 2 1 AG2400 Clamping hub diameter up to K 38 mm...
Page 90: ......