background image

USA:

 P.O. Box 1289 

 Elyria, Ohio 44036

Canada:

 R.W. Beckett Canada, Ltd. 

 Unit #3, 430 Laird Road 

 Guelph, Ontario N1G 3X7

www.beckettcorp.com

Part Number 6104 BCF23 R14, Printed in the U.S.A. 08/10

The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its “Products” from 
Beckett for resale, or for incorporation into a product for resale (“Customers”), that its equipment is free 
from defects in material and workmanship. To qualify for warranty bene

fi

 ts, products must be installed by a 

quali

fi

 ed service agency in full compliance with all codes and authorities having jurisdiction, and used within 

the tolerances of Beckett’s de

fi

 ned product speci

fi

 cations. 

To review the complete warranty policy and duration of coverage for a speci

fi

 c product, or obtain a written 

copy of warranty form 61545, please choose one of the following options:

Visit our website at: www.beckettcorp.com/warranty 
Email your request to:  [email protected]
Write to:  R. W. Beckett Corporation, P. O. Box 1289, Elyria, OH 44036

NOTE:  Beckett is not responsible for any labor cost for removal and replacement of equipment.

THIS WARRANTY IS LIMITED TO THE PRECISE TERMS SET FORTH ABOVE, AND PROVIDES 
EXCLUSIVE REMEDIES EXPRESSLY IN LIEU OF ALL OTHER REMEDIES, AND IN PARTICULAR 
THERE SHALL BE EXCLUDED THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS 
FOR A PARTICULAR PURPOSE.  IN NO EVENT WILL BECKETT BE LIABLE FOR ANY INCIDENTAL OR 
CONSEQUENTIAL DAMAGE OF ANY NATURE.  Beckett neither assumes, nor authorizes any person to 
assume for Beckett, any other liability or obligation in connection with the sale of this equipment. Beckett’s 
liability and Customer’s exclusive remedy is limited to the cost of the product.

1.
2.
3.

Limited Warranty Information

Summary of Contents for CF1400

Page 1: ...tion start up or service work Save this manual for future reference y y y Incorrect installation adjustment or misuse of this burner could result in death severe personal injury or substantial propert...

Page 2: ...which your burner ap pliance is installed Make sure Air ventilation openings are clean and unob structed Nothing is blocking burner inlet air openings No combustible materials are stored near the heat...

Page 3: ...e read all instructions before proceeding Follow all instructions completely This equipment must be installed adjusted and started by a qualified service agency that is licensed and experienced with a...

Page 4: ...ed in an isolated room provided with outside combustion air Clearances With the burner installed in the appliance there must be adequate space in front of and on the sides of the burner to allow acces...

Page 5: ...he appliance dimensions are smaller than recommended reduce the firing rate accordingly Table 1 Nozzle Capacities Rated gph 100 psig Pressure Pounds per square inch 125 140 150 175 200 250 275 300 3 0...

Page 6: ...ing rate required On the CF2300 there are two tube arrangements available Tube A 7 0 to 19 9 GPH per Figure 3 Tube B 10 0 to 19 9 GPH per Figure 3 The CF2300 maximum firing capacity depends on the fir...

Page 7: ...loss of burner operation resulting in no heat an unplanned process interruption work stoppage and the potential for frozen plumbing or other cold weather property damage Protect Against Dust and Mois...

Page 8: ...he end of the nozzle line leaving the nut loosely placed so the plates can be moved Connect the high voltage leads from the ignition transformer to the electrodes Check and adjust if necessary the cri...

Page 9: ...s than dimension D in Figure 8 Thread the pipe into the flange Secure the burner to the appliance by tightening the nuts on the burner flange mounting studs 1 2 3 4 5 6 Figure 7 Adjusting Plate Assy F...

Page 10: ...ump k Return line to oil tank m One pipe by pass loop 3 8 p Air bleed valve Figure 9 One pipe Oil Flow with B Pump SK9940 Figure 10 Two pipe Oil Flow with B Pump SK9939 Use continuous lengths of heavy...

Page 11: ...s energized A flame should be established within the factory set trial for ignition time lockout time Lockout The control has shut down for one of the following safety reasons The trial for ignition l...

Page 12: ...equence The control will continue to Recycle each time the flame is lost until it reaches a pre set time allotment The control will then go into Hard Lockout instead of recycle This feature prevents e...

Page 13: ...13 CF1400 CF2300 Burner Manual Figure 13 Typical Wiring 7505P Section Wire the Burner...

Page 14: ...de The burner starts at Low goes to High after the flame stabilization 1 2 3 4 5 6 a period Flame is extinguished when the load is satisfied or a limit opens and the burner is sent to Motor Off Delay...

Page 15: ...tart up Professional Installation and Service Required Incorrect installation and mishandling of start up could lead to equipment malfunction and result in asphyxiation explosion or fire This burner m...

Page 16: ...0 6 17 0 60 16 0 7 18 0 70 17 0 8 19 0 80 18 0 9 20 0 90 19 0 100 20 0 B 0 12 5 0 1 13 0 10 10 0 2 14 0 20 13 0 3 15 0 30 14 0 4 16 0 40 15 0 5 17 0 50 16 0 6 18 0 60 17 0 7 18 5 70 18 0 8 19 0 80 18...

Page 17: ...to its low fire setting This initial setting should be adequate for starting the burner at low fire Once the burner is in operation the air setting will be adjusted for best performance as discussed l...

Page 18: ...stment Vapor Filled Appliance Allow the unit to cool off and all vapors to dissipate before attempting another start Oil Flooded Appliance Shut off the electrical power and the oil supply to the burne...

Page 19: ...Burner Move the low fire hold switch to the low fire hold position to hold burner in low fire when started Verify that the air adjusting cam Figure 17 item d has been set to the initial low fire air...

Page 20: ...3 12 44 DIA 51498 13 92 DIA 51630 16 00 DIA Flange A Flange B Flange C Check the pump pressure and cutoff function Check primary control safety lockout timing Check ignition system for proper operatio...

Page 21: ...21 CF1400 CF2300 Burner Manual SK9930 3 2 4 5 6 1 SK9931 8 9 7 Section Replacement Parts Figure 19a Burner Replacement Parts...

Page 22: ...5994U 5201301U 51204U 5201302U 14 Sight glass All models 31346 31346 15 Head assembly 5978 51203 16 Electrode assembly All models 51212 51212 17 Ignition leads 8 1 4 long 11 3 4 long 15 1 4 long 19 1...

Page 23: ...23 CF1400 CF2300 Burner Manual Figure 19b Burner Replacement Parts Continued SK9936 SK9932 SK9930 14 13 12 10 20 11 21 22 23 15 16 17 18 19...

Page 24: ...copy of warranty form 61545 please choose one of the following options Visit our website at www beckettcorp com warranty Email your request to rwb customer service beckettcorp com Write to R W Beckett...

Reviews: