2.4 Installation Requirements
The installation of the device(s) depends on the type of aircraft and its equipment and therefore only
general information can be given in this section.
The installation of REU6100 into an aircraft may be carried out by an authorized
installation company. The country regulations always have to be obeyed.
•
The device must not be opened.
•
Keep an efficient distance of the devices with integrated ventilator fans in
order to ensure free circulation of the cooling air.
•
The installation area must have a minimum distance of 30 cm from the
magnetic aircraft compass, to prevent any interference to the magnetic
compass.
•
Forced cooling is not required.
REU6100 is made for installation in cockpit environment of fixed and rotary
wing aircraft.
These limitations apply for the installation:
•
Installations must be in accordance with appropriate EASA or FAA
approved guidelines.
•
The personnel installing this device must ensure that the aircraft
installation conditions are within the ETSO/TSO standards applicable
for the specific type or class of aircraft.
•
The conditions and tests for ETSO/TSO approval of this article are
minimum performance standards.
•
The equipment is not qualified for installation in areas with fluid
contamination.
•
Changes or modifications made to this equipment not expressly
approved in written form by Becker may void the authorization to
operate this equipment.