General information regarding the levels
The control unit has several levels. Operation of the door (OPEN, CLOSE) is possible in the status level only.
Status level
Display of door status, error reports, input statuses, operation of the door (opening, closing),
etc.
Parameterisation level
In order to parameterise the control unit, you must switch to the parameterisation level. In the
parameterisation level, the door cannot be operated. 3 parameterisation levels are available. In
the operator level, different times can be set. For further settings, you must switch to the pass-
word protected technician level. The door manufacturer level is available for the manufacturer of
the door.
General operating information regarding the status level
In the status level, messages concerning the status of the door and fault messages are displayed. If various messages are active,
only the message with the highest priority is displayed. Further existing error messages, as well as the clock counter, maintenance
counter and switching states of the inputs, can be called up by turning the rotary-push button. If, after 15 seconds, no further ac-
tivation follows, the current status or latest message is displayed once again.
Operating step
Selection
Information
DDT (L)
Previous display The next active error message or previous piece of information is displayed.
By turning to the left, the previous piece of information can be called up.
DDT (R)
Next display
The previous active error message or next piece of information is displayed.
By turning to the right, the next piece of information can be called up.
DDT activation
Selection
Explanation
7-segment display
1
F
atal error
F.
2
1
1
(Minor)
E
rror
E.
0
4
4
Information (
I
nformation)
I.
3
5
1
DDT (R)
2
Current status e.g. CLOSE limit position
_
E
c
_
DDT (R)
3
Clock counter
n
3
DDT (R)
4
Maintenance counter
9.
9
9
7
DDT (R)
5
Software version
┌
0.
0
9
DDT (R)
6
Status of the safety edge SE1
S
E
1.
1
DDT (R)
7
Status of the safety edge SE2
S
E
2.
1
DDT (R)
8
Status of the function inputs 1 to 32
┌
0
1.
1
DDT (R)
9
Checksum of the software
3
F
6
5
Error message
If an error has occurred, the current error message or piece of information is shown on the display. The last current error message
is always shown and the status display is thus covered over. Further error messages can be called up by turning the DDT to the left.
Fatal error
The door drive no longer operates.
Minor error
The door drive now only operates in dead-man mode (possibly dependent upon direction).
Information
Individual door functions are disrupted, e.g. if parameterisation is missing or maintenance is
due.
Active errors which have not yet been rectified are indicated by a decimal point in the first segment (e.g. F
.
212.). Errors/messages
which are still to be acknowledged are indicated by a decimal point in the last segment (e.g. F212
.
). To acknowledge, a user inter-
vention is required, e.g. pressing and holding the DDT (TT). Errors can continue to be tracked in the history.
Concerning this, also see the table Information display and messages.
10