FEATURES
On Appearance
DIMENSION
TECHNICAL DATA
Power Supply: 95 ~ 240 VAC, 50 ~ 60HZ
Sensor: NTC3950, 10K±1%
Accuracy: ±0.5
℃
Set Temp. Range: 5 -35
Dispaly Temp. Range: 5 ~ 99
Ambient Temp.: 0 ~ 45
℃
Storage Temp.: -5 ~ 45
℃
Timing Error: < 1%
Shell Material: PC +ABS ( Fireproof)
Wire Terminals: Wire 2 x 1.5 mm2 or 1 x 2.5 mm2
Current Load
:
℃
℃
BEFORE WIRING AND INSTALLING
3. Installer must be a trained, experienced service technician.
CAUTION
Electrical Shock or Equipment Damage Hazard. Can shock
individuals or short equipment circuitry.
WIRING
INSTALLATION
Step 1. Keep power off. See Fig 1.
Fig 1
Step 3. Connect power supply, load into the appropriate terminals.
(see “Wiring your thermostat” for details and Fig 3).
the box. See Fig 4.
HOME SCREEN QUICK REFERENCE
During Power On
1. Power On/off:
Press to turn the thermostat on/off.
2. Manual & Programmable
Touch (mode) to change between manual mode and programme
In programmable mode, the period icon will show on the right side.
could not be
adjusted.If the user want to change, please go to manual mode or
programmable mode.
In the mode of manual, press
to set the desired temperature.
OPERATION
Touch the icon to set minute, hour and weekday (1 = Monday,
2 = Tuesday etc.) by using the arrows.
Press and hold the for 3 seconds to lock/unlock your thermostat
5. Locking your Thermostat
7. Checking the Temperature of Floor Sensor
Press and hold the arrow for 3 seconds to display the temp. of
floor sensor.
accept the program schedule made via the APP on your device (see
your thermostat (NOT via your smartphone/tablet) simply follow the
thermostat and smartphone/tablet.
e
m
m
a
r
g
o
r
p
d
n
a
e
d
o
m
l
a
u
n
a
m
n
e
e
w
t
e
b
e
g
n
a
h
c
o
t
h
c
u
o
T
In programme mode, touch and hold the icon un
ti
l the weekday.
Press the icon
(1st period).
Repeat this process for periods 2, 3, 4 and 5 6.
Press the icon
Press
once more to confirm and exit.
1 means Monday will show one by one on
the right side).
C
P
S
as below:
20
6. Interated with
Amazon Echo ,Google Home.
8. No limit to add rooms and support device sharing with family.
During Power Off
When power is off, press and hol
d
available
Then press to scroll through
BHT-001Series Round Thermostat
User Guide
Welcome
Thank you for your purchase.
Your new thermostat will provide uniform and comfortable
temperature control throughout every room in your property. We
bring together technology,
materials to provide you with a safe, reliable product combined with
sleek, contemporary design.
programming manual for comprehensive
thermostat. Please also
ensure
a suitably qualified person
installs your thermostat and
In the box you will find
Thermostat
Screws
User Guide
1pc
2pc
1pc
QC Passed
1pc
Floor Sensor (2.5m) 1pc
MODEL DEFINITION
WIFI TYPE
90mm
Front
Side
Back
Unit: mm
14.0
25.5
60.0
50.3
50.3
Fig 3
Fig 2
Fig 4
Fig 5
Fig 6
the screen .
the screen .
Mon.
Set
Temp.
Tue.
Set
Temp.
Wed.
Set
Temp.
Thu.
Set
Temp.
Fri.
Set
Temp.
Sat.
Set
Temp.
Sun.
Set
Temp.
06:00
20
℃
06:00
20
℃
06:00
20
℃
06:00
20
℃
06:00
20
℃
06:00
20
℃
06:00
20
℃
08:00
15
℃
08:00
20
℃
08:00
20
℃
08:00
15
℃
08:00
15
℃
08:00
15
℃
08:00
15
℃
11:30
15
℃
11:30
20
℃
11:30
20
℃
11:30
15
℃
11:30
15
℃
11:30
15
℃
11:30
15
℃
13:30
15
℃
13:30
20
℃
13:30
20
℃
13:30
15
℃
13:30
15
℃
13:30
15
℃
13:30
15
℃
17:00
22
℃
17:00
20
℃
17:00
20
℃
17:00
22
℃
17:00
22
℃
17:00
22
℃
17:00
22
℃
22:00
15
℃
22:00
15
℃
22:00
15
℃
22:00
15
℃
22:00
15
℃
22:00
15
℃
22:00
15
℃
5. 86mm hidden box and european 60mm round box is suitable.
6. White, black housing creates your colorful life.
2. Modern appearance leads to modern life.
3. Beau
2. 0.5°C Accuracy keeps temperature within the level you set.
3.
4. Data memory when power is off.
5. 7 days six periods programmable maximize comfort and economy.
Humidity sensor helps you know the humidity around you.
temperature.
other days’
.
Code
Func on
Se ng and op ons
Default
1
Temperature
Compensa on
-9 to +9
℃
(for internal sensor)
-2
2
Deadzone Temp.
0.5-4
℃
(for internal sensor)
1
3
Display Mode
0
:
display both se emp. and room temp.
1
:
display se emp. only
00
4
Sensor Types
In
:
Internal Sensor
(
to control or limi he
temperature
)
Ou: External Sensor
(
to control or limi he
temperature
)
Al: Internal and External Sensor
(
Internal sensor to
control temperature, external sensor to limit
temperature
)
Note: Please make sure the right sensor. If choose the
wrong or bad one, LCD will display Err.
AL
5
Min. Set Temp.
5-15
℃
5
6
Max. Set Temp.
15-45
℃
35
7
Frost Protec on
On/o
ff
0: O
ff
; 1: On
1
8
Frost Protec on
se ng.
0-10
℃
5
9
High Temperature
Protec on Se ng.
40-70
℃
45
A
Bu ons Standby
Brightness
3 ~ 99
4
B
Backlight Standby
Brightness
3 ~ 99
4
C
Device Status
when power on
0: Keep the power o
ff
.
1: Keep the status before power o
ff
1
D
Deadzone Temp.
0.5-5
℃
(for external sensor)
1
Return to factory
0
E
GC: Water/Gas Boiler, 5A
L: Backlight
P: Weekly Programmable
W: Wifi
S2: Both internal sensor and floor external sensor
For example: BHT-001 GCLW
5
88.0
88.0
5A
(
AC95~240V
IP20
N L
1
2
3 4
M
Close
Open
5
6
NTC
GA
L1
N1
LOAD
IP20
N L
1
2
3 4
NTC
5
6
GB
IP20
N L
1
2
3 4
5
6
NTC
GC
Dry Contact
A (RED)
Modbus
B (WHITE)
A (RED)
Modbus
B (WHITE)
A (RED)
Modbus
B (WHITE)
AC95~240V
AC95~240V
Room Temp.
Set Temp.
Wifi EZ Mode
Manual
Time Display
Power On/off
Floor Temp.
Mode
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
⑬
⑭
⑮
⑯
Lock
Clock
Up
Down
Period 1 to Period 6
Monday To Sunday
⑧
⑨
⑩
⑪
①
②
⑥
⑦
③
④
⑤
⑫
⑬
⑭
⑮
⑯
Temp. Display
17
PM AM
17
18
19
20
18
19
20
21
ON OFF
21
Wifi EZ Mode
Wifi AP Mode
ABOUT YOUR THERMOSTATS
The BHT-001 series range has been developed to control electric