background image

QUICK START GUIDE

RST055A UPS Pack

Suitable for most Beam equipment requiring 

5V  or  15V  input  power,  Iridium  9555  phone 

and  most  of  the  USB  powered  portable  

devices including iPhone®*

Beam Communications Pty Ltd 

5.  User Modes

www.beamcommunications.com

[email protected]

TEL:  +61 3 8588 4500

FAX:  +61 3 9560 9055

        Safety Information - Important!

Please  read  this  guide  carefully  before  installing  or  using 

the  RST055A  UPS  Pack.  Failing  to  follow  instructions  may  

compromise  the  safety  of  the  product  and  may  result  in  

personal injury and/or equipment damage. Please consult your 

supplier if you have any further question.

USRQSG005202

5.1 Charging Mode

•  Plug the power source (110/240V AC/DC adaptor, car cigarette 

lighter  input  cable  or  vehicle  installation  cable)  into  the  input 

connector.

•  The green INPUT LED will be turned on to indicate the presence 

of input power.

•  The red CHG LED will be turned on to indicate the fast charging 

for the internal battery pack. When the battery is fully charged, this 

LED will be switched off.

5.2 Stand-Alone Mode

Main Output:

•  DO NOT connect anything to the main output before setting the 

voltage correctly!!!

•  Set the output voltage to 5V or 15V by sliding the selection switch.
•  Plug  the  appropriate  3-way  main  output  cable  into  the  main 

connector.

•  Plug the other end of the cable into your equipment, for example, 

PotsDOCK.

•  If your equipment draws more than 2A current, the red Overload 

LED will be turned on!

USB Output:

•  Plug the type A end of your USB cable into the USB output.
•  Plug the other end of the cable into your equipment, for example, 

the 9555 phone.

•  If your equipment draws more than 1A current, the red Overload 

LED will be turned on!

Please  note  that  both  main  output  and  USB  output  can  be  used 

simultaneously providing up to 3A current.

5.3 UPS Mode

•  Plug the input power source as per instructed in 5.1.
•  Connect your equipment to the main and/or USB outputs as per 

instructed in 5.2.

•  In case a power failure occurred, the UPS Pack would continue to 

power your equipment and the duration will depend on the battery 

capacity at the power failure.

•  When  the  battery  capacity  in  the  UPS  Pack  is  low  and  your 

equipment is drawing full current from the outputs, it will take much 

longer to charge the UPS Pack. Thus, it is recommended to fully 

charge the UPS Pack before using it as a UPS.

6.  Battery Capacity

7.  Troubleshooting

•  Press the battery capacity push button.
•  The five green LEDs next to the push button will display a 

pattern showing the remaining battery capacity.

5 LEDs on

80% to 100%

4 LEDs on

60% to 80%

3 LEDs on

40% to 60%

2 LEDs on

20% to 40%

1 LED on

10% to 20%

1 LED

 flash

<10%

Q: My equipment is plugged into the output port, but it is not 

being powered by the UPS Pack.

A: Please check the battery capacity of the UPS Pack.

Q: My equipment is plugged into the output port, but it is not 

being powered by the UPS Pack and the red LED next to 

the output is turned on.

A: Your equipment is consuming more than 2A (main 

output) or 1A (USB output) current. Please check the power 

rating of your equipment. Your equipment may also be 

faulty causing a short circuit.

Q: The battery capacity indicator is not correct. UPS pack 

has been charging for hours, but it indicates empty when 

the push button is pressed.

A: Please discharge the UPS Pack completely and then 

recharge it without any load connected.

* iPhone® is a registered trademark of Apple Corporation

Reviews: