BEA LZR RS300 User Manual Download Page 1

1

LZR

®

- RS300

SAFETY SENSOR 

FOR EXTERNAL RAILWAY DOORS

EN

User’s Guide

 

for product version 0700 and more

This user’s guide is an informative document and 
can not be seen as a commitment of result.

Summary of Contents for LZR RS300

Page 1: ...1 LZR RS300 SAFETY SENSOR FOR EXTERNAL RAILWAY DOORS EN User s Guide for product version 0700 and more This user s guide is an informative document and can not be seen as a commitment of result ...

Page 2: ...2 ...

Page 3: ...t be held responsible for incorrect installations or inappropriate adjustments of the sensor SAFETY SENSOR FOR EXTERNAL RAILWAY DOORS 1 Detection LED relay 1 not used 2 Detection LED relay 2 safety field 3 Error LED 4 Power LED Factory values Possible remote control adjustments LED flashes slowly TIP The LEDs can be switched off by remote control 1 laser sweep emission 2 laser sweep reception 3 LE...

Page 4: ...o the visible red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel may install and adjust the sensor Avoid extreme vibrations Do not cover the front screens Avoid moving objects and light sources in the detection field Avoid condensation Avoid the presence of smoke and fog in the detection field Avoid expo...

Page 5: ...the cable opening If drilling an opening is not possible use the cable conduits on the back side of the bracket Position the bracket and fasten the 4 screws firmly Open the protection cover plug the connector and position the cable in the slit Close the protection cover and fasten it firmly Turn the sensor until the two triangles are face to face Position the housing on the bracket APPLICATIONS CU...

Page 6: ...tection field with the hex key Lock the position of the mounting bracket to avoid malfunctioning in case of extreme vibrations Unlock the sensor and activate the visible laser beams The visible laser beams indicate approximately the postion of the first curtain and limit the angle of the detection field The visible laser beams stay activated for 15 minutes or can be turned off the same way they we...

Page 7: ...to avoid disturbances Wait for the sensor to learn its environment or lock it by remote control left right MOUNTING SIDE Stay outside of the detection field to avoid disturbances Select the corresponding mounting side The sensor then learns its environment and automatically determines the detection field s Both red LEDs flash slowly and the 3 visible laser beams automatically light up during 30 se...

Page 8: ... 50 cm FACTORY VALUES IMMUNITY FILTER MIN OBJECT SIZE OUTPUT CONFIGURATION approximate values A active P passive UNCOVERED ZONE DETECTION CURTAINS permanent 0 5 m FIELD WIDTH FIELD HEIGHT no safety field 0 5 m indoor outdoor low outdoor med outdoor high indoor outdoor low outdoor med outdoor high Increased sensitivity detection of black objects Increased immunity to rain snow fog EX C1 C2 are deac...

Page 9: ...LUES SAVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote control If the red LED flashes quickly after unlocking you need to enter an access code from 1 to 4 digits X THE NUMBER OF FLASHES INDICATES THE VALUE OF THE PARAMETER field width 4 2 m field width i...

Page 10: ...ll The polarity of the power supply is inverted Check cable and connexion Check the size of the fields Launch a teach in Step out of the field and or remove the any object s from the field Activate the 3 red beams and check if the position of the sensor is correct If not adjust the hex screws Verify the field size Launch a teach in Check the position of the sensor Check the mounting side setting I...

Page 11: ...r side 5 W 1 8 A max 80 ms 35 V 2 m typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V AC 80 mA resistive tON 5 ms tOFF 5 ms typ 30 Ω 0 7 V 20 mA 10 µA 2 optocouplers galvanic isolated polarity free 30 V DC over voltage protected Log H 8 V DC Log L 3 V DC 5 ms 1 blue LED power on status 1 orange LED error status 2 bi coloured LEDs detection output status green no ...

Page 12: ...0 is in conformity with the basic requirements and the other relevant provisions of the directives 2014 35 EU 2011 65 EU and 2014 30 EU The complete declaration of conformity is available on our website This product should be disposed of separately from unsorted municipal waste BEA Original instructions 42 7510 V5 06 20 PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING ...