4.5 DC protector
The DC protector turns to “OFF” (2) automatically when electric device
being connected to the generator is operating and current above the
rated flows. To use this equipment again, turn on DC protector by
pressing its button to “ON” (1)
(1) “ON”
Direct current is output.
(2) “OFF”
Direct current is not output.
CAUTION
• Reduce the load of the connected electric device below the specified
rated output of the generator if the DC protector turns off. If the DC
protector turns off again, stop using the device immediately and
consult our company authorized dealer.
4.6 Engine smart control (ESC)
①
(1) “ON”
When the ESC switch is turned to “ON”, the economy control unit
controls the engine speed according to the connected load. The results
are better fuel consumption and less noise.
(2) “OFF”
When the ESC switch is turned to“OFF”, the engine runs at the rated
r/min(4500r/min) regard-less of whether is a load connected or not.
TIP:
The ESC must be turned to“OFF”when using electric devices that
require a large starting current, such as a compressor of a submergible
pump.
4.7 Fuel tank cap
Remove the fuel tank cap by turning it counterclockwise.
4.8 Fuel tank cap air vent knob
The fuel tank cap (2) is provided with an air vent knob to (1) stop fuel
flow. The air vent knob must be turned to “ON”. This will allow fuel to flow
to the carburetor and the engine to run. When the engine is not in use,
turn the air vent knob to “OFF” to stop fuel flow.
4.9 Ground (Earth) terminal
Ground (Earth) terminal (1) connects the earth line for prevention of
electric shock. When the electric device is grounded, always the ground
the generator.