Be Modern 580 Deluxe Inset User Instructions Download Page 1

580 GAS FIRE – INSTALLATION & SERVICING INSTRUCTIONS 

 

 

 
 

Inset Live Fuel Effect 

MODEL 580 Deluxe Inset 

 

For use on Natural Gas at a supply pressure of 20mbars in G.B / I.E 

 

 

 

 

 

USER’S 

INSTRUCTIONS 

 

These instructions must be handed to the user 

to be kept in a safe place for future reference 

 

Part No. 200380   

Issue 4 

GC No. 32-210-25 

Patent application No. 0123387.3 

 

 

 

 
 

 
 

 

 

Be Modern Customer Care, Bede Industrial Estate 

Jarrow, Tyne and Wear, NE32 3BE 

Tel: (0191) 489 8266 option 4

 

Summary of Contents for 580 Deluxe Inset

Page 1: ...upply pressure of 20mbars in G B I E USER S INSTRUCTIONS These instructions must be handed to the user to be kept in a safe place for future reference Part No 200380 Issue 4 GC No 32 210 25 Patent app...

Page 2: ...included in same carton Trim Fire Front and Ashpan Cover 4kg Safety Environment Recommendations If carrying distance exceeds 10m or stairs steps are involved then 2 person lifting should be considere...

Page 3: ...8mm comp Spark Gap 4mm 0 5mm Inlet Pressure 20 mbar Overall Dimension Width Height Depth 470mm 585mm 180mm General Installation Requirements Prior to installation ensure that the local distribution c...

Page 4: ...than the catchment around the face of the opening and the flue terminal to allow dispersion of flue gases The fire must only be installed on non combustible walls with a flat area minimum 30mm require...

Page 5: ...ncrease as shown in Diagram 1D Wooden combustible materials may be fitted to within 100mm on either side of the fire minimum 660 between uprights providing it does not project forward more than 100mm...

Page 6: ...be wired back into the fireplace opening There are also four fixing holes in the fire front frame if required Check that the rear face of the opening is structurally sound and fit the eyelets and wall...

Page 7: ...must touch the rear fibre bed at its extreme edges and should fit inside the up stand on the front coal support bracket B Positioning the coals pebbles This fire is supplied with 15 large coals pebble...

Page 8: ...remove the protective film it is advisable to take the trim off the fire Remove the protective film Refit the trim to the fire with the magnets attached Three Piece Clip on Trim Remove the protective...

Page 9: ...fer to those Use the two M5 screws and two M5 nuts to fix fret to fire as follows 1 Thread nut onto screws up to the screw head 2 Insert the two M5 screws into the back of the fret and screw in as far...

Page 10: ...Inlet Elbow The pressure test point is positioned on the inlet elbow The inlet pressure can be verified and the soundness of all the gas joints tested up to the fire can now be checked The fire is set...

Page 11: ...f the gas supply before servicing the appliance Ensure that the appliance is cold Clean any soot or debris from the burner port and ignition ladder Clean any soot or debris from the ceramic parts usin...

Page 12: ...Black Deluxe Fibre Board Set 101367 H05 926 5 1 Brick Effect Black Deluxe Fibre Board Set 101318 H05 927 6 1 Plain Cream Deluxe Fibre Board Set 101319 H05 928 7 1 Gas Control Tap 101996 H50 950 8 1 E...

Page 13: ...ter approximately 30 minutes Ventilation This appliance does not normally require additional ventilation into the room For Republic of Ireland ventilation may be required Refer to local rules in force...

Page 14: ...s failed to ignite after 3 attempts you MUST wait for 3 minutes prior to attempting to re light Having confirmed that the burner is alight keep the control knob pressed in for further 10 seconds and t...